Available Internal Data
3A1704N
9
Available Internal Data
The following internal data with this system can be viewed and modified by your fieldbus master.
NOTE:
Refer to appropriate system manual for machine operation instructions.
CGM Output from PLC Input (Byte)
Byte No.
Most Significant Byte
Least Significant Byte
Description
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
0
0,1
1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0
Status
1
2,3
3 SHOT PART OF SHOT/SEQ
2 OPERATING MODE
Shot
Mode
2
4,5
5 CONDITIONING
4 SEQUENCE PART OF SHOT/SEQ
Cond.
Seq.
3
6,7
7 RED TANK FILL
6 BLUE TANK FILL
R Tank B Tank
4
8,9
8,9,10,11 ERRORS TO ACKNOWLEDGE (ARRAY OF 2 WORDS)
Errors to
Acknowledge
5
10,11
6
12,13
13.7 13.6 13.5 13.4 13.3 13.2 13.1 13.0 12.7 12.6 12.5 12.4 12.3 12.2 12.1 12.0
Units
7
14,15
14,15,16,17 FLOW RATE SET POINT (ARRAY OF 2 WORDS)
Flow Rate Set
Point
8
16,17
9
18,19
18,19,20,21 DISPENSE AMOUNT SET POINT (ARRAY OF 2 WORDS)
Dispense
Amount Set
Point
10
20,21
11
22,23
22,23 MATERIAL RATIO SET POINT (1 WORD)
Ratio St PT
12
24,25
24,25,26,27 RED PUMP PRESSURE ACTUAL (ARRAY OF 2 WORDS)
Red Pump
Pressure Actual
13
26,27
14
28,29
28,29,30,31 BLUE PUMP PRESSURE ACTUAL (ARRAY OF 2 WORDS)
Blue Pump
Pressure Actual
15
30,31
16
32,33
32,33,34,35 PUMP FLOW RATE ACTUAL (ARRAY OF 2 WORDS)
Flow Rate
Actual
17
34,35
18
36,37
36,37 MATERIAL RATIO ACTUAL (1 WORD)
Ratio Actual
19
38,39
38,39,40,41 DISPENSE AMOUNT ACTUAL (ARRAY OF 2 WORDS)
Dispense
Amount Actual
20
40,41
21
42,43
42,43,44,45 DISPENSE DURATION ACTUAL (ARRAY OF 2 WORDS)
Dispense
Duration Actual
22
44,45
23
46,47
46,47 BLUE INLINE TEMPERATURE ACTUAL (1 WORD)
B Inline Act.
24
48,49
48,49 BLUE HOSE TEMPERATURE ACTUAL (1 WORD)
B Hose Act.
25
50,51
50,51 RED INLINE TEMPERATURE ACTUAL (1 WORD)
R Inline Act.
26
52,53
52,53 RED HOSE TEMPERATURE ACTUAL (1 WORD)
R Hose Act.
27
54,55
54,55 BLUE TANK TEMPERATURE ACTUAL (1 WORD)
B Tank Act.
28
56,57
56,57 RED TANK TEMPERATURE ACTUAL (1 WORD)
R Tank Act.
29
58,59
58,59 BLUE CHILLER TEMPERATURE ACTUAL (1 WORD)
B Chill Act.
30
60,61
60,61 RED CHILLER TEMPERATURE ACTUAL (1 WORD)
R Chill Act.
31
62,63
62,63 BLUE INLINE TEMPERATURE SETPOINT (1 WORD)
B Inline St Pt.
32
64,65
64,65 BLUE HOSE TEMPERATURE SETPOINT (1 WORD)
B Hose St Pt.
33
66,67
66,67, RED INLINE TEMPERATURE SET POINT (1 WORD)
R Inline St Pt.
34
68,69
68,69 RED HOSE TEMPERATURE SETPOINT (1 WORD)
R Hose St Pt.
35
70,71
70,71 BLUE TANK TEMPERATURE SETPOINT (1 WORD)
B Tank St Pt.
36
72,73
72,73 RED TANK TEMPERATURE SETPOINT (1 WORD)
R Tank St Pt.
37
74,75
74,75 BLUE CHILLER TEMPERATURE SETPOINT (1 WORD)
B Chill St Pt.
38
76,77
76,77 RED CHILLER TEMPERATURE SETPOINT (1 WORD)
R Chill St Pt.