Setup
313536U
11
Fluid Line
Fluid Filter:
Use a 25 micron stainless steel element to
filter particles from the fluid as it leaves the pump.
Fluid Drain Valve:
Required in your system, to relieve
fluid pressure in the hose and gun.
Gun Setup
1. Verify hydraulic power pack is off.
2. Install hydraulic hoses to power pack.
3. Use a 7/16 in. JIC male-male adapter at the gun end
to connect hoses together. This creates a hydraulic
fluid circulation loop.
4. Turn on the power pack. Circulate oil for 10 minutes
to purge air from hydraulic hoses.
NOTE:
Pressure should not increase while air is purged
from hoses.
5. Turn off power pack. Verify no pressure exists in
hoses.
6. Remove the 7/16 in. JIC male-male adapter con-
necting the hydraulic hoses.
7. Attach hydraulic hoses to the gun.
8. Set power pack to manual mode.
9. Attach trigger switch cable and proximity switch
cable (if applicable) to gun and power pack.
10. Verify power pack pressure is 1800 - 2500 psi.
Adjust pressure as required.
Trapped air can cause the pump to cycle unexpectedly,
which could result in serious injury from splashing or
moving parts.
Customer supplied hydraulic hoses must be at least
1/4 in. inner diameter and rated to at least 2500 maxi-
mum working pressure.
F
IG
. 6
ti14495a
F
IG
. 7
F
IG
. 8
ti14496a