Maintenance
16
3A1937C
Maintenance
Temperature Control Module
Clean
Keep heat sink fins clean at all times. Wipe the fins
clean with a dry cloth or clean them using compressed
air.
NOTE:
Do not use conductive cleaning solvents on the tem-
perature control modules.
Install Upgrade Token
NOTE:
The Motor Control Module, Fluid Control Mod-
ule, and Temperature Control Module connection to the
system is temporarily disabled during the installation of
upgrade tokens.
To install software upgrades:
1. Use correct software token stated in the table. See
Graco Control Architecture
™
Module Programming
manual for instructions.
NOTE: Upgrade all modules in the system to the
software version on the token, even if you are
replacing only one or two modules. Different soft-
ware versions may not be compatible.
All data in the module (System Settings, USB Logs,
Recipes, Maintenance Counters) may be reset to
factory default settings. Download all settings and
user preferences to a USB before the upgrade, for
ease of restoring them following the upgrade.
See manuals for locations of specific GCA compo-
nents.
The software version history for each system can be
viewed in the technical support section at
www.graco.com.
F
IG
. 5: Clean Heat Sink Fins
ti12353a1
Heat Sink Fins
Token
Application
16G365
VPM:
- High Power Temperature Control Module
F
IG
. 6: Remove Access Cover
ti12354a1