Repair
311075ZAB
43
Fluid Heaters (if supplied)
See your heater manual for repair and parts information,
which is supplied with heated units.
1. Follow
2. Follow the
, page 22.
3. The control section of the heater can be repaired in
place. Remove the heater to clean the fluid section.
See your manual for repair and parts information.
Pressure Transducers
1. Follow
, page 36.
2. Follow the
3. Remove the access cover (39) at the back of the
control module to expose control board (406).
4. Disconnect the transducer cables from J3 and J8 at
the board. See F
. 14, page 42. Reverse A and B
connections and check if the status code follows the
bad transducer. See
5. Reconnect the good transducer to the proper
connector. Disconnect the failed transducer from
the board, and unscrew from the base of the fluid
heater (heated units) or transducer manifold
(nonheated units).
6. Install the o-ring (60) on the new transducer (58),
7. Install the transducer in the heater or manifold. Mark
the board end of cable with tape (red= transducer A,
blue= transducer B).
8. Route the cable through the channel to the control
module.
9. Connect the transducer cable at the board; see F
F
IG
. 15 Transducers
60
58
Heated Units
Nonheated Units
60
58
TI7026a
TI7027a