Installation
18
311075ZAB
Connect the Fluid Hoses
1. Connect the fluid supply hoses to the outlet hose
connections (R).
NOTE:
Use the
red hoses for component A (ISO), and
the blue hoses for component B (RES). The fittings are
sized to prevent connection errors.
2. Connect the other end of the hoses to the A and B
inputs of the gun.
3.
Heated units only:
connect the recirculation hoses
from gun recirculation ports to the connections (S).
Connect the Air Hoses
1.
For air operated guns:
connect the gun air hose to
the gun air input and to the air filter outlet (Z).
NOTE:
If you are using more than one hose bundle, join
the air hoses with the nipple (305) provided with the
hose bundle.
2.
For heated units with Fusion guns:
connect the
supplied ball valve and quick-disconnect coupler to
the gun air hose. Connect the coupler to the gun air
fitting.
Connect the Main Air Supply
1. Connect the main air supply to the quick disconnect
fitting (Q) on the unit. The air supply hose must be
at least 5/16 in. (8 mm) ID up to 50 ft (15 m) or 3/8
in. (10 mm) ID up to 100 ft (30 m).
NOTE:
The Air Filter/Moisture Separator (Z) is equipped
with an automatic moisture drain.
Flush Before First Use
The Reactor E-10 is tested with a plasticizer oil at the
factory. Flush out the oil with a compatible solvent
before spraying. See
, page 28.
F
IG
. 6 Hose Connections
WLD
WLD
R
Q
Z
A (ISO)
B (RES)
AIR
Non-heated Units
Heated Units
R
S
Q
A (ISO)
AIR
Z
B (RES)