Installing Software
1.
Run Setup.exe from the CD and follow the setup
prompts.
2.
Click Finish to complete the installation.
Connecting Unit to PC
1.
With the unit turned off, connect the RS-232 cable to
the unit’s data port (A). F
If connecting RS-232 cable to a unit used in a Haz-
ardous location, use Kit 246397/248403 and see
F
. 2 for installation requirements.
2.
Turn on air to start the unit.
Changing the Serial/COM Port
1.
After installing the software, start the XtremeMX or
ProMixEZ Setup program from your Start menu.
2.
Tera Term window opens, showing the current COM
port being used.
3.
Click Setup > Serial Port.
4.
The Serial Port Setup window opens. Click the
desired COM port in the Port list.
5.
Click OK.
6.
Press Enter on the PC keyboard and verify that the
“Welcome to Graco… appears. If it does not appear,
refer to Software Troublshooting on page 7.
7.
Click Setup > Save Setup.
8.
Save the file as teraterm.ini. Xtreme Mix in
directory:
C:\Program Files\Graco\Graco XtremeMX log 1.02.
or ProMix Easy in directory:
C:\Program Files\Graco\Graco ProMixEZ log 1.01.
F
IG
. 2
The program was tested on Microsoft
®
Windows 98
and Windows XP.
F
IG
. 1
PSI
Bar
MPa
B
A
B
A
0
A
If a serial port is not available, use a USB-to-serial
port adapter (available at most retail electronics
stores). Instructions for setup using an adapter
begin on page 4.
Hazardous Area
Class I, Div 1, Group D
Input Entity per:
Vmax (Ui) = 16 V
Imax (Ii) = 20 mA
Pmax = 320 mW
Li = 1 mH
Ci = 1.9
μ
F
Control
Pump Position
Sensors
Conduit & Cable
Conduit & Cable
Intrinsically Safe
Barrier Interface
Interface Cable
Laptop PC
A
B
Non-hazardous Area Only