Reassembly
14
309577A
13.
To reconnect pump B:
a.
Turn main power ON
.
b.
Enter jog mode. Run motor until compo-
nent B connecting rod is at bottom of its
stroke.
c.
Shut main power OFF
.
d.
Ensure locknut (G) is screwed on pump
with flat side up. Screw pump into bear-
ing housing (M) until pin holes align.
Push pin (F) in. Pull retaining spring (E)
down. See F
e.
Continue screwing pump into housing
until fluid outlet (D) is aligned with steel
tube and top threads are +/- 1/16 in. (2
mm) of bearing face (N). See F
f.
Tighten locknut (G) by hitting firmly with
a non-sparking hammer. See F
g.
Reconnect fluid inlet (C) and outlet (D).
To reconnect pump A, see page 15.
F
IG
. 2. Reconnect Pump (Pump A Shown)
C
D
F
E
G
M
N
1
Flat side faces up.
1
TI2602A