5
309317
PRESSURE RELIEF
– Follow this procedure when cleaning, repairing or shuting down
sprayer
1. Turn off turbine.
2. Unlatch cup
TIP SELECTION
A Tip consists of a fluid
nozzle, and fluid needle.
Use the following chart
for recommendations.
Fluid Set
Tip Size
Fluid Usage
#2
244123
0.8 mm
(0.032 in)
Ink, dye and non–wiping stain.
#3
244124
1.3 mm
(0.051 in)
Water base lacquer, urethane, varnish, stain, and automotive finish.
#4
244125
1.8 mm
(0.071 in)
Lacquer, urethane, varnish, stain, primer, enamel and epoxy.
#5
244126
2.2 mm
(0.087 in)
Lacquer, urethane, varnish, stain, primer, enamel, epoxy and
higher output industrial finishes.
#6
244127
2.5 mm
(0.098 in)
Latex, multi–spec, oil wall paint, industrial finishes, buty-
rate, and nitrate dope.
Installing the Fluid Set
Trigger the gun whenever you tighten or remove the nozzle. This keeps the needle seat away from
the nozzle seating surface and prevents the seat from being scratched.
CAUTION
For Cup Guns
Follow these
instructions whenever
you stop spraying.
1. Turn off air supply to the pot.
2 quart
8069A
02882
For Pressure Feed Guns
2. Open pressure relief (A) on
pot until pressure is completely
relieved. Close relief.
A
A
Follow these
instructions whenever
you stop spraying.
Summary of Contents for 244113