309117 5
Installation
TI0403
Fig. 1
KEY
A
Air Line Filter
B
Air Line Lubricator
C*
Bleed-type Air Shutoff Valve
D
Pump Air Regulator
E*
Fluid Drain Valve
F
Fluid Shutoff Valve
G
Fluid Filter
H*
Grounded Fluid Hose
J
Pump
K
Air Line
L
Air Pressure Regulator
M
Pump Fluid Inlet
N
In-line Fluid Filter
P
Pattern Adjustment Valve Knob
R
Pressure Gauge
S
Trigger Safety
T
Pump Runaway Valve
U*
Fluid Pressure Regulator
V
Air Shutoff Valve
W
Fluid Swivel
Y*
Pump Ground Wire
*Equipment required for safe operation of the
system. Must be purchased separately.
C
A
D
C
B
T
J
V
F
R
G
E
M
H
L
K
N
W
S
P
E
Y
U
Typical Installation
The typical installation shown in Fig. 1 is only a guide
for selecting and installing air-assisted spray systems.
Contact your Graco distributor for assistance in de-
signing a system to meet your needs.
Ventilate the Spray Booth
WARNING
To prevent hazardous concentrations of
toxic and/or flammable vapors, spray
only in a properly ventilated spray booth.
Do not operate the spray gun unless
ventilation fans are operating.
Check and follow all of the National,
State and Local codes regarding air ex-
haust velocity requirements.
Check and follow all local safety and fire codes.