Programmed Integrated Circuit
Chip Kit
Part No. 243549
Before Beginning
1.
Write down the Informer setup parameters. They
will be needed for reprogramming later. Refer to
manual 309102 for further information.
2.
Put on the grounding strap provided.
CAUTION
Wear the grounding strap provided with the kit to
avoid shorting out the circuit board.
3.
Follow the Pressure Relief Procedure at right.
Pressure Relief Procedure
WARNING
INJECTION HAZARD
The system pressure must be manually relieved to
prevent the system from starting or spraying acci-
dentally. Fluid under high pressure can be injected
through the skin and cause serious injury. To
reduce the risk of an injury from injection, splashing
fluid, or moving parts, follow the Pressure Relief
Procedure whenever you:
D
are instructed to relieve the pressure,
D
stop spraying,
D
check or service any of the system equipment.
1.
Turn off the fluid supply to the meter.
2.
Shut off all electrical power to the fluid system.
3.
Follow the Pressure Relief Procedure for your fluid