Installation
307400R
5
Installation
Grounding
1.
Pump:
use a ground wire and clamp as instructed in
your pump instruction manual.
2.
Fluid hoses:
Use only grounded hoses with a maxi-
mum of 500 feet (150 m) combined hose length to
ensure grounding continuity.
3.
Spray gun, manifold, or dispensing valve:
obtain
grounding through connection to a properly
grounded connection to a properly grounded fluid
hose and sprayer.
4.
Object being sprayed:
according to local code.
5.
Supply containers:
according to local code.
6.
All solvent pails
used when flushing, according to
local code. Use only
metal pails,
which are conduc-
tive. Do not place the pail on a non-conductive sur-
face, such as paper or cardboard, which interrupts
the grounding continuity.
7.
To maintain grounding continuity when flushing or
relieving pressure,
always hold a metal part of the
gun firmly to the side of a
grounded metal
pail, then
trigger the gun.
Installation
For assistance in setting up a plural component system,
contact your Graco distributor
.
This will help assure that
you select the proper type and size equipment for your
job.
Use the spacer (40), screws (37), nuts (38) and
lock-washers (39) provided to mount the manifold.
Connect the supply lines from your pump to the mani-
fold inlets (R & Q).
Connect your static mixer or hose to the material outlet
(S). Model 24H002 has a 1/2 npt(m) outlet. Model
241692 includes a static mixer with a 3/8 npt(m) outlet.
The equipment must be grounded to reduce the risk
of static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape wire
for the electric current.