308-845

10

Parts List

Wall-Mount Packages with Fluid Pressure Regulators

Model No. 240–349,  Delta Spray air spray package
Model No. 240–350,  Delta Spray HVLP package
Model No. 240–351,  no hoses (31) or gun (30)
Model No. 240–352,  PRO 3500sc electrostatic package
Model No. 240–353,  PRO 4500sc electrostatic package

Ref.
No.

Part No.

Description

Qty.

1

240–210

SHIELD ASSY, front

Contains 1a to 1h, shown in Fig. 2 on
page 9

1

2

110–789

WASHER, flat

2

3

100–014

SCREW

2

5

104–123

WASHER, spring lock

4

6

102–025

NUT, hex

4

7

192–994

HANDLE, shield

1

8

D31–331

PUMP, Husky 307

See instruction manual 308–553

1

9

054–139

TUBE, flexible

75 in.

10

111–864

CONNECTOR, male

1

11

188–181

PLUG, bung, airtight

1

12

111–276

SCREW, thumb

1

13

111–863

CONNECTION, union

1

15

054–175

HOSE; Nylon

10 in.

16

054–188

TUBE, PTFE 

R

9 in.

17

188–285

BRACKET, wall

1

19

112–899

WASHER, lock

1

20

112–903

NUT, hex

1

21

114–370

FITTING, tube, quick-connect

1

24

104–119

SCREW, cap, hex head

4

25

192–996

SHIELD, back

1

26

104–029

LUG, grounding

1

27

054–139

TUBE; Nylon

11.5 in.

28

189–436

NIPPLE

1

29

Y

189–220

LABEL, warning

1

Ref.
No.

Part No.

Description

Qty.

30

239–542

GUN, Delta Spray, air spray

Model 240–349
See instruction manual 308–742

1

239–561

GUN, Delta Spray, HVLP

Model 240–350
See instruction manual 308–741

1

222–300

GUN, PRO 3500sc, electrostatic

Model 240–352
See instruction manual 307–912

1

224–200

GUN, PRO 4500sc, electrostatic

Model 240–353
See instruction manual 308–131

1

31

240–421

HOSE ASSY, air spray/HVLP;
25 ft (7.6 m)  

Delta packages

1

240–425

HOSE ASSY, PRO gun;
25 ft (7.6 m)  

PRO packages

1

32

100–333

SCREW, cap, hex head

2

33

114–369

FITTING, tube, quick-connect

1

34

193–251

LABEL, product

Delta packages

1

193–252

LABEL, product

PRO packages

1

37

238–909

GROUND WIRE & CLAMP ASSY 1

38

188–171

TUBE, suction

1

39

113–521

ELBOW, street

1

40

114–456

ELBOW, street

1

50

236–449

REGULATOR, fluid pressure;

0–30 psi (0–207 kPa, 0–2 bar)
Model 240–350
See instruction manual 308–325

1

236–450

REGULATOR, fluid pressure;

0–100 psi (0–0.6 MPa, 0–7 bar)
All Models except 240–350
See instruction manual 308–325

1

Y

Extra Warning labels are available for free.

Summary of Contents for 240-349

Page 1: ...MPa 7 bar Maximum Fluid Working Pressure 100 psi 0 7 MPa 7 bar Maximum Air Inlet Pressure Packages with Fluid Pressure Regulators Model No 240 349 with hoses and Delta Spray air spray gun Model No 240...

Page 2: ...1A 308845 Instruction Manual Parts List Changes This page contains a summary of changes or additions that do not appear in the contents of the manual...

Page 3: ...1B 308845 Notes...

Page 4: ...D Tighten all fluid connections before each use D Check the hoses tubes and couplings daily Replace parts immediately if worn damaged or loose Permanently coupled hoses cannot be repaired FIRE AND EXP...

Page 5: ...cal Data section of all the equipment manuals Read the fluid manufacturer s warnings D Route the hoses away from traffic areas sharp edges moving parts and hot surfaces Do not expose Graco hoses to te...

Page 6: ...erence numbers and letters in parentheses refer to the callouts in the figures and the parts lists on pages 10 and 12 Preparing the Operator Anybody who operates this system should be trained in the s...

Page 7: ...oughly with a compatible solvent See Flushing the System on page 8 Grounding WARNING To reduce the risk of static sparking the entire system must be grounded Check your local electrical code for detai...

Page 8: ...the gun With the gun air triggered set the gun air pressure to 60 psi 413 kPa 4 bar NOTE Gun air pressure higher than 60 psi 413 kPa 4 bar will cause excessive overspray and lowered efficiency 4 If y...

Page 9: ...the gun air triggered set the gun air pressure to 60 psi 413 kPa 4 bar 6 Hold the gun against and aimed into a grounded metal waste pail and fully trigger the gun If your system has a fluid pressure r...

Page 10: ...ately 3 Place the suction tube into a grounded metal pail of compatible solvent 4 Make sure the air regulators E and F are closed NOTE The gun air regulator F always stays closed during flushing 5 Ope...

Page 11: ...tion manual 308 167 2 1c 160 430 GAUGE pressure 2 1d 114 362 VALVE ball 1 1e 159 840 ADAPTER 2 1f 188 077 NIPPLE 1 1g 114 369 FITTING tube 1 1h 114 370 FITTING tube 1 Front Shield Assembly Orderable P...

Page 12: ...SHIELD back 1 26 104 029 LUG grounding 1 27 054 139 TUBE Nylon 11 5 in 28 189 436 NIPPLE 1 29Y 189 220 LABEL warning 1 Ref No Part No Description Qty 30 239 542 GUN Delta Spray air spray Model 240 34...

Page 13: ...39 40 50 28 7 30 222 300 shown 12 27 27 15 15 Wall Mount Packages with Fluid Pressure Regulators Model No 240 349 Delta Spray air spray package Model No 240 350 Delta Spray HVLP package Model No 240 3...

Page 14: ...188 TUBE PTFE R 9 in 17 188 285 BRACKET wall 1 19 112 899 WASHER lock 1 20 112 903 NUT hex 1 21 114 370 FITTING tube quick connect 1 24 104 119 SCREW cap hex head 4 Ref No Part No Description Qty 25...

Page 15: ...9 13 1 8 5 6 24 24 9 9 10 16 17 21 25 29 34 30 32 33 40 50 12 27 27 15 15 38 16 3 7 40 Wall Mount Packages with Surge Tanks Model No 240 361 Delta Spray air spray package Model No 240 362 Delta Spray...

Page 16: ...and the other elbow 104 5 Thread the nipple 105 with the elbow 104 attached to it into the elbow 104 that you threaded into the pump outlet 6 Thread the fluid filter 101 onto the male threads of the e...

Page 17: ...chrome plate Wetted parts other fluid hoses and tubing nylon PTFE R Wetted parts fluid fittings nylon acetal 304 316 stainless steel Weight without hoses or gun packages with fluid pressure regulator...

Page 18: ...ranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any...