background image

10

308645

Service

Fig. 8

23

1

Torque to 26–32 ft-lb
(35–43 N.m)

A

B

C

D

1

4

05970

NOTE: 

The needle (C), diffuser/seat (A), gasket (B)

and locknut (D) must be replaced together. They are
included in Repair Kit 218070.

Disassembly

 

(See Fig. 8)

1.

Follow the 

Pressure Relief Procedure

 on page

5.

2.

Remove the tip guard assembly. See Fig. 2.

3.

Squeeze the trigger while unscrewing the diffuser/
seat (A) and gasket (B).

4.

Remove the locknut (D) and end cap (23).

5.

Tap the rear of the gun with a plastic mallet to
push the needle assembly out the front.

Reassembly

 

 (See Fig. 8)

1.

Guide the threaded end of the needle assembly
into the front of the gun.

2.

Install the end cap, aligning its guides with the
holes in the rear of the gun. Install the locknut (D)
loosely.

3.

Squeeze the trigger while installing the gasket (B)
and diffuser/seat (A). Torque the diffuser seat to
26–32 ft-lb (35–43 N.m).

4.

If the gun handle (6) was removed, hand tighten it
into the fluid housing (26); it should fit easily.

5.

Adjust the needle before using the gun. Procedure
below.

6.

Be sure the trigger guard and tip guard are
installed before using the gun.

Adjusting the needle

 (See Fig. 9)

1.

Engage the gun safety latch.

2.

Hold the gun with the nozzle straight up.

3.

Hold your finger against the trigger with light
pressure. Turn the locknut (D) clockwise until you

feel

 the trigger depress slightly.

4.

Turn the adjusting nut 3/4 turn 

counterclockwise.

5.

Connect the fluid hose. Install the tip guard and
prime the system. Trigger the gun and release it.
The fluid flow should stop immediately. Engage the
safety latch and try to trigger the gun. No fluid
should flow. 

If the gun fails either test

, relieve

pressure, disconnect the hose and readjust the
needle.

Fig. 9

1

D

2

1

2

Engage trigger
safety latch

Arrows indicate
clockwise turn

05972

Summary of Contents for 238350

Page 1: ...SSURE Model 238350 Series A Includes RACr DripLesst Guard 515 size SwitchTipt and 4 finger trigger Model 824004 Series A Includes RACr DripLesst Guard 515 size SwitchTipt and 4 finger trigger Model 23...

Page 2: ...urpose If you are not sure call your Graco distributor D Do not alter or modify this equipment D Check equipment daily Repair or replace worn or damaged parts immediately D Do not exceed the maximum w...

Page 3: ...y when you stop spraying D Follow the Pressure Relief Procedure on page 5 if the spray tip clogs and before cleaning checking or servicing the equipment D Tighten all fluid connections before operatin...

Page 4: ...n the spray area D Extinguish all open flames or pilot lights in the spray area D Do not smoke in the spray area D Do not turn on or off any light switch in the spray area while operating or if fumes...

Page 5: ...st be manually relieved to prevent the system from starting or spraying accidentally Fluid under high pressure can be injected through the skin and cause serious injury To reduce the risk of an injury...

Page 6: ...p wear 7 If adjusting the pressure does not give a good spray pattern follow the Pressure Relief Proce dure on page 5 and then try another tip size 8 Use a full open full close triggering action Hold...

Page 7: ...andard Flat Tip and Guard 1 Lock the gun trigger safety open the pressure drain valve CAUTION Never soak the entire gun in solvent Prolonged exposure to solvent can ruin the packings 2 Remove the spra...

Page 8: ...rd and spray tip 3 Start the sprayer and adjust it to the lowest pressure 4 Aim the gun into a grounded metal pail while holding it firmly to the pail Trigger the gun If the fluid emitted is not diffu...

Page 9: ...ip Soak and clean the parts 3 Put the pump intake in a grounded pail of water or solvent 4 Start the pump at its lowest pressure 5 Trigger the gun into the original pail When water or solvent appears...

Page 10: ...and diffuser seat A Torque the diffuser seat to 26 32 ft lb 35 43 N m 4 If the gun handle 6 was removed hand tighten it into the fluid housing 26 it should fit easily 5 Adjust the needle before using...

Page 11: ...ent 4 Remove swivel 15 guard retainer 42 and cushion o ring 43 5 Save guard retainer and cushion o ring 05968 Fig 10 6 12 42 43 15 Reassembly 1 Clean internal thread of handle 6 2 Install guard retain...

Page 12: ...Drawing n41 n40 12 5 42 16 20 18 21 22n 23 26 32 37 1 31 33 1 Included with 1 Model 238350 Series A Model 824004 Series A Model 239045 Series A 1 Purchase separately 2 2 6 43 15 05962 17 45 45 2 Inclu...

Page 13: ...AINER ELEMENT 1 standard 50 mesh 20 179763 SPRING 1 21 179722 SPRING RETAINER color coded blue for standard 50 mesh filter 1 22n 179733 GASKET 1 23 191244 END CAP 1 26 190973 FLUID HOUSING 1 31 105334...

Page 14: ...rds is included with every Graco airless gun 237859 RACR DripLesst Guard Order SwitchTip separately See your distributor for available sizes 220222 Standard DripLesst Tip Guard Order flat tip separate...

Page 15: ...t 1 4 npsm m swivel Maximum Material Temperature 120_F 50_C Sound Data Sound Pressure Level 78 dB A Sound Power Level 87 dB A Measured while spraying waterbase paint gravity 1 36 through a 517 tip at...

Page 16: ...but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach...

Reviews: