6
308370
Installation
Recommended Hose Sizes
(general purpose)
Fluid
Air
For runs of:
Use:
For runs of:
Use:
0 to 35 ft (0 to 11 m)
3/8” ID
35 to 100 ft (11 to 30 m) 1/2” ID
100 to 200 ft
(30 to 61 m)
3/4” ID
0 to 50 ft (0 to 15 m)
5/16” ID
50 to 100 ft (15 to 30 m) 3/8” ID
100 ft+ (30 m+)
1/2” ID
Installing An Agitator
1.
Follow the
Pressure Relief Procedure
on
page 5.
WARNING
PRESSURIZED EQUIPMENT HAZARD
This is a pressurized tank.
Alway
s
follow the
Pres-
sure Relief Procedure
on page 5 before opening
the tank cover or fill port. This reduces the risk of
serious injury, including splashing in the eyes or on
the skin, or injury from moving parts. These injuries
can result if the tank pressure is not fully relieved.
2.
Remove the cover (26) from the tank. Remove the
hex jam nut (14) from bottom of the cover.
Remove the o-ring (20), adapter plug (17), and
handle (4). Keep the hex jam nut (14). See Fig. 3.
3.
Fit the gasket (217) under the coupling housing
(112), and place the motor shaft (111) through
cover’s center hole. Screw the hex jam nut (14)
onto the coupling housing, and torque it to 50 ft-lb
(68 N-m). See Fig. 4.
4.
Position the shaft coupling (218) over the motor
shaft (111), and tighten the top setscrew into shaft.
Insert the shaft (220) into the shaft coupling, and
tighten the lower setscrew into the shaft. Thread
on the nut (221), mixer blade (222), washer (223),
and nut (224). See Fig. 4.
5.
Connect the elbow (105) to the manifold (10) in
place of plug. Connect the agitator hose (114) to
the elbow (105). See Fig 4.
Fig. 4
03093A
112
111
14
221
222
223
224
10
114
105
220
217
218
113