Installation

Recommended Hose Sizes

 (general purpose)

Fluid

Air

For runs of:

Use:

For runs of:

Use:

0 to 35 ft (0 to 11 m)

3/8” ID

35 to 100 ft (11 to 30 m) 1/2” ID

100 to 200 ft
(30 to 61 m)

3/4” ID

0 to 50 ft (0 to 15 m)

5/16” ID

50 to 100 ft (15 to 30 m) 3/8”   ID

100 ft+ (30 m+)

1/2”   ID

Installing An Agitator

1.

Follow the 

Pressure Relief Procedure

 on

page 5.

WARNING

PRESSURIZED EQUIPMENT HAZARD

This is a pressurized tank.

 

Alway

s

 follow the 

Pres-

sure Relief Procedure

 on page 5 before opening

the tank cover or fill port. This reduces the risk of
serious injury, including splashing in the eyes or on
the skin, or injury from moving parts. These injuries
can result if the tank pressure is not fully relieved.

2.

Remove the cover (26) from the tank.  Remove the
hex jam nut (14) from bottom of the cover.
Remove the o-ring (20), adapter plug (17), and
handle (4). Keep the hex jam nut (14).  See Fig. 3.

3.

Fit the gasket (217) under the coupling housing
(112), and place the motor shaft (111) through
cover’s center hole.  Screw the hex jam nut (14)
onto the coupling housing, and torque it to 50 ft-lb
(68 N-m).  See Fig. 4.

4.

Position the shaft coupling (218) over the motor
shaft (111), and tighten the top setscrew into shaft.
Insert the shaft (220) into the shaft coupling, and
tighten the lower setscrew into the shaft.  Thread
on the nut (221), mixer blade (222), washer (223),
and nut (224).  See Fig. 4.

5.

Connect the elbow (105) to the manifold (10) in
place of plug.  Connect the agitator hose (114) to
the elbow (105).  See Fig 4.

Fig. 4

03093A

112

111

14

221

222

223

224

10

114

105

220

217

218

113

Summary of Contents for 236155

Page 1: ...essure Regulated Tank 100 psi 0 7 MPa 7 bar 308370L Low Pressure Tank Low Pressure Tank with Agitator High Pressure Tank High Pressure Tank with Agitator 03092A 03094B 03096A 03098B 0359 II 1 2 G T6 P...

Page 2: ...rofessional use only D Read all instruction manuals tags and labels before operating the equipment D Use the equipment only for its intended purpose If you are not sure call your Graco distributor D D...

Page 3: ...nect all equipment in the spray area D Before operating this equipment extinguish all open flames or pilot lights in the spray area D Do not smoke in the spray area D Do not turn on or off any light s...

Page 4: ...zed to withstand the pressures in the system 03287A Fig 1 KEY A Air supply hose B Main air supply C Ground clamp wire Required D Atomizing air hose E Fluid hose F Air spray gun G Air regulator filter...

Page 5: ...escaping through the drain cock fitting before removing the cover or opening the fill port 4 Leave the drain cock fitting 7 open until you have reinstalled the cover or fill port 15 Fig 2 03286A Groun...

Page 6: ...tank pressure is not fully relieved 2 Remove the cover 26 from the tank Remove the hex jam nut 14 from bottom of the cover Remove the o ring 20 adapter plug 17 and handle 4 Keep the hex jam nut 14 See...

Page 7: ...isk of serious injury including splashing in the eyes or on the skin and property damage never exceed the maximum air and fluid working pressure of the lowest rated component in your system 2 Open the...

Page 8: ...lator See separate instruction manual 307204 for care and maintenance of air regulator Maintaining the Agitator Air Motor See Fig 5 Lubricate agitator motor as follows whenever it will be shut down fo...

Page 9: ...3a 108 105286 BEARING flange 1 109 105285 SEAL shaft spring loaded 1 110 156969 MUFFLER 1 4 npt m 1 111 188883 SHAFT motor 2 gal 1 112 188882 HOUSING coupling 2 gal 1 113 206264 VALVE needle 1 114 16...

Page 10: ...awing Low Pressure Stainless Steel ASME Tank Model 236155 24 11 4 29 31 3 5 12 18 1 Tank assembly includes tank 24 gasket 25 cover 26 and plug 27 2 28 15 9 32 30 16 7 27 03091A 29a 6 25 21 26 14 23 13...

Page 11: ...1 1 8 27 npt f x 1 4 18 npt m 20 165053 O RING packing PTFE 1 21 185531 TUBE siphon sst 1 22 175078 LABEL Warning not shown 1 23n 236439 VALVE ball sst 1 3 8 18 npsm m x 3 8 18 npt m See 307 068 for...

Page 12: ...sure Stainless Steel ASME Tank w Agitator Model 236156 03093B 26 33 35 3 5 12 18 1 32 15 9 36 34 16 7 29 33a 6 27 21 28 14 25 13 3 10 37 See page 9 for agitator parts Tank assembly includes tank 26 ga...

Page 13: ...4 18 npt m 21 185531 TUBE siphon sst 1 23 175078 LABEL Warning not shown 1 25n 236439 VALVE ball sst 1 3 8 18 npsm m x 3 8 18 npt m See 307068 for parts 26 236086 TANK 2 gal size sst 1 27n 117572 GASK...

Page 14: ...awing High Pressure Stainless Steel ASME Tank Model 236157 24 11 4 29 31 3 5 18 1 28 15 9 32 30 7 33 6 25 21 26 14 23 13 17 20 3 35 10 36 27 2 16 12 03095A Tank assembly includes tank 24 gasket 25 cov...

Page 15: ...npt m 20 165053 O RING packing PTFE 1 21 185531 TUBE siphon sst 1 22 175078 LABEL Warning not shown 1 23n 236439 VALVE ball sst 1 3 8 18 npsm m x 3 8 18 npt m See 307068 for parts 24 236086 TANK 2 ga...

Page 16: ...ssure Stainless Steel ASME Tank w Agitator Model 236158 03097B 26 32 35 3 5 12 18 1 33 15 9 36 34 7 29 37 6 27 22 28 14 25 13 3 10 38 16 See page 9 for agitator parts Tank assembly includes tank 26 ga...

Page 17: ...rning not shown 1 22 185531 TUBE siphon sst 1 25n 236439 VALVE ball sst 1 3 8 18 npsm m x 3 8 18 npt m See 307068 for parts 26 236086 TANK 2 gal size sst 1 27n 117572 GASKET Santoprener 1 28 COVER tan...

Page 18: ...convert to a high pressure regulator assembly Gun Air Regulator Kit 235042 100 psi 0 7 MPa 7 bar Working Pressure To supply atomizing air to a spray gun from the pressure pot Stainless Steel Mixer Bl...

Page 19: ...a 7 bar Relief Valve Setting 100 psi 0 7 MPa 7 bar Air Inlet Size 1 4 18 npt m Fluid Outlet Size 3 8 18 npsm R3 8 19 compound thread Bottom Outlet Size 3 4 14 npt f Weight 30 25 lb 13 7 kg without agi...

Page 20: ...ve The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequent...

Reviews: