background image

Operation

309925B

5

Operation

1.

Pull out regulator knob and turn fully counter-clock-
wise. Open relief valve on cup lid (counter-clock-
wise).

2.

Open lid and fill cup with desired sprayable material.

3.

Close lid and seal by turning clockwise, hand-tight.

4.

Close relief valve on cup lid hand-tight, turning 
clockwise.

5.

Set regulator (not supplied) to desired PSI (this is 
your atomizing air).

6.

Slowly turn cup regulator knob clockwise while 
pulling gun trigger fully back to start material flow. 
Continue turning regulator knob clockwise until 
desired material flow is achieved. Push in regulator 
knob to lock.

7.

To decrease paint flow, pull out regulator knob and 
turn counter-clockwise to lower cup pressure. 

8.

Open the relief valve to bleed off excess pressure. 

9.

Reseal relief valve. Repeat step 6. The cup lid has a 
check valve that prevents the cup from losing 
pressure until the relief valve is opened.

Maximum cup pressure is 50 psi (345 kPa, 3.4 
bar).

Atomizing air for the spray gun can be adjusted 
with an air adjusting valve installed on the 
spray gun.

To achieve desired cup pressure always start 
at a lower pressure and increase to the desired 
setting.

Summary of Contents for 234413

Page 1: ...registered to I S EN ISO 9001 309925B Instructions Parts List 2 Liter Pressure Cup Model 234413 50 psi 345 kPa 3 4 bar Maximum Fluid Pressure 160 psi 1 1 MPa 11 bar Maximum Air Inlet Pressure This ma...

Page 2: ...gering into pail If there is static sparking or you feel a shock stop operation immediately Do not use equipment until you identify and correct the problem PRESSURIZED ALUMINUM PARTS HAZARD Do not use...

Page 3: ...pment to help protect you from serious injury including eye injury inhalation of toxic fumes burns and hearing loss This equipment includes but is not limited to Protective eye wear Gloves clothing an...

Page 4: ...un Air Pressure Set the gun air pressure regulator for the minimum pressure needed to atomize your fluid See your gun manual for recommended settings Material Preparation Follow manufacturer s directi...

Page 5: ...aterial flow Continue turning regulator knob clockwise until desired material flow is achieved Push in regulator knob to lock 7 To decrease paint flow pull out regulator knob and turn counter clockwis...

Page 6: ...and add compatible solvent 5 Repeat steps 3 and 4 in Operation page 5 Spray until clean solvent appears Cup and gun material passages should be clean now 6 Follow Pressure Relief Procedure page 3 7 E...

Page 7: ...Replace Safety valve setting too high Replace Valve spring broken or distorted Replace Diaphragm damaged Replace Insufficient pressure in cup Check valve stuck shut Clean or replace Safety valve sett...

Page 8: ...4 for parts U22801 TUBE fluid U22802 LID cup U22803 RING cup U22807 GASKET lid U22820 VALVE safety U22825 NIPPLE U22835 VALVE check assembly U22845 NUT assembly U22850 HANDLE cup assembly U22860 INLET...

Page 9: ...id pressure 50 psi 345 kPa 3 4 bar Maximum air inlet pressure 160 psi 1 1 MPa 11 bar Safety valve release 50 psi 345 kPa 3 4 bar Weight empty 3 lbs 3 oz 1 45 kg Cup capacity 2 liters 0 53 gal Hose con...

Page 10: ...workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS...