Graco 223646 Instructions-Parts List Manual Download Page 5

Installation

308048N

5

Installation

Refer to the complete pump manual for detailed 

installation information or contact your Graco 

distributor. 

NOTE

: A 1 in. npt seal (7) is supplied in a plastic bag 

with the motor. Thread the seal onto the threads of your 

hydraulic return line fitting (A). Thread the fitting into the 

upper housing (53) and torque as needed. Then tighten 

the seal (7) against the motor to provide a secure seal. 

See Fig. 1.

F

IG

. 1 ___________________________________________

Maximum Hydraulic Input Pressure

The maximum safe hydraulic input pressure to this 

motor depends on the lower displacement pump to 

which it is connected.

Refer to the lower manual and the pump manual for 

the maximum fluid working pressure and the ratio. 

Never exceed the maximum fluid working pressure of 

the pump. Serious injury or damage to the equipment 

may result.

To reduce the risk of serious injury whenever you are 

instructed to relieve pressure, always follow the 

Pressure Relief Procedure on page 8.
Be sure you always shut off the supply line shutoff 

valve (E) first, and then the return line shutoff valve. 

This is to prevent over pressurizing the motor or its 

seals. When starting up the hydraulic system, open 

the return line shutoff valve first.

NOTICE

Keep the hydraulic system clean

To reduce the risk of damaging the hydraulic power 

supply, blow out all hydraulic lines with air, flush 

thoroughly with solvent, and then blow out with air 

again before connecting the lines to the motor.
Always plug the hydraulic inlets, outlets and lines when 

disconnecting them to avoid introducing dirt and other 

contaminants into the system.
Carefully follow the manufacturer’s recommendations 

on reservoir and filter cleaning, and periodic changes 

of hydraulic fluid. 

NOTICE

Recommended Hydraulic Oil

Use Graco-approved Hydraulic Oil, Part No. 169236 (5 

gal) or 207428 (1 gal)) or a premium, ISO grade 46 

petroleum-based hydraulic oil containing rust and 

oxidation inhibitors and anti-wear agents.

Before using any other type of oil in this motor, contact 

your Graco distributor. Unauthorized use of lesser 

grade oil or substitutes may void the warranty.

Hydraulic Oil Working Temperature

The recommended hydraulic oil operating temperature 

is 80 - 115° F (27 - 45° C). The motor seals will wear 

faster and leakage may occur if the pump is operated 

at higher oil temperatures.

If the hydraulic oil temperature approaches 130° F (54° 

C), check the hydraulic fluid supply cooling system, 

filters, etc. and clean or repair as needed.

7

53

A

04467

Summary of Contents for 223646

Page 1: ...ofessional use only Model 223646 Series C and D 1500 psi 10 MPa 103 bar Maximum Hydraulic Fluid Input Pressure Important Safety Instructions Read all warnings and instructions in this manual before us...

Page 2: ...ngs has been updated This cylindrical design replaces the square housing design previously used There is no performance change associated with this update If replacement of a square housing is necessa...

Page 3: ...damaged parts immediately with genuine manufacturer s replacement parts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure...

Page 4: ...ug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail Do not use pail lin...

Page 5: ...s seals When starting up the hydraulic system open the return line shutoff valve first NOTICE Keep the hydraulic system clean To reduce the risk of damaging the hydraulic power supply blow out all hyd...

Page 6: ...ded fluid hose and pump Fluid supply container according to local code Object being sprayed according to local code Any pails used when flushing Use only metal grounded pails when flushing Make firm m...

Page 7: ...e the pressure 3 Stop the pump at the bottom of its stroke 4 Disconnect the displacement pump hoses Disconnect the hydraulic hoses and plug all hydraulic connections and lines to prevent contamination...

Page 8: ...tainer 30b Remove the trip rod 31 from the piston 30a 19 Remove the trip rod locknut 27 and piston stop 28 If the piston is replaced remove the spring 26 to use in the new piston 20 Remove the bearing...

Page 9: ...12 Install the end cap 47 using thread sealant on the socket screws 51 13 Lubricate the threads of the tie rods 57 and install them with lockwashers 52 If the crown nuts 44 were removed reinstall them...

Page 10: ...t be positioned with joints opposed Lips must face up toward top of motor Model 235345 use only one seal 23 Torque to 70 80 ft lb 95 108 N m Apply thread lubricant to lower threads Concave surface fac...

Page 11: ...1 32 26 30a 17 30b 27 28 56 54 54a 3 3a 1 20 16 11 25 24 23 29 57 33 33 24 2 15 14 21 13 12 19 18 A A B B 4342 40 41 39 9 30c Model 223646 Series C NOTE See the service section for important torque an...

Page 12: ...NUT hex jam 5 8 18 4 20 101577 SCREW machine hex hd No 10 20 x 0 375 in 1 21 110800 O RING buna N 1 23 186223 BEARING piston bronze filled PTFE 1 24 110795 SEAL u cup polyurethane 2 25 186218 HOUSING...

Page 13: ...Parts Cylindrical Housings 308048N 13 Parts Cylindrical Housings Model 223646 Series D 25a b 30cX 30bX X30a...

Page 14: ...am 5 8 18 4 20 101577 SCREW machine hex hd No 10 20 x 0 375 in 1 21 110800 O RING buna N 1 23 186223 BEARING piston bronze filled PTFE 1 24 110795 SEAL u cup polyurethane 2 25 20B232 KIT replacement h...

Page 15: ...Hydraulic fluid consumption 1 gal 3 8 liter per 5 cycles Effective piston area 4 9 sq in 31 6 cm2 Piston rod diameter 2 5 in 64 mm Stroke length 4 69 in 119 1 mm Thrust at 1500 psi 10 MPa 103 bar 7300...

Page 16: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRAN...