8
308147
Installation
(AIR-POWERED PUMPS)
NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.
Fig. 3 is only a guide for selecting and installing sys-
tem components and accessories. Contact your Graco
distributor for assistance in designing a system to suit
your particular needs.
Assembling Models 237555, 233127, and
233128
If you have Models 237555, 233127, or 233128
Pumps, assemble the displacement pump (105) to the
Premier air motor (101) as instructed on page 18.
Fig. 3
KEY
A
Pump
B
Wall Bracket
C
Pump Runaway Valve
D
Air Line Lubricator
E
Bleed-Type Master Air Valve
(required, for pump)
F
Pump Air Regulator
G
Air Manifold
H
Electrically Conductive Air Supply Hose
J
Air Line Filter
K
Bleed-Type Master Air Valve
(for accessories)
L
Fluid Filter
M
Fluid Drain Valve (required)
N
Electrically Conductive Fluid Supply Hose
P
Fluid Whip Hose
R
Gun/Valve Swivel
S
Airless Spray Gun
or Dispensing Valve
T
Drum Suction Kit
Y
Ground Wire (required; see page 6
for installation instructions)
A
B
C
D
E
F
G
H
J
K
M
N
P
Y
MAIN AIR LINE
200 LITER (55 GAL.) DRUM
L
R
S
T
TYPICAL INSTALLATION
0626C