background image

2

308113

2

Table of Contents

Graco Phone Number

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . 

Technical Data

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Warnings

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Operation

Electronic Meter

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Dispense Valves 

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Troubleshooting 

Electronic Meter

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Dispense Valve

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Service

Electronic Meter

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Dispense Valve

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Parts Lists and Drawings

Dispense Valve

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Unmetered Dispense Valves

11

. . . . . . . . . . . . . . . . . . 

Electronic Meter

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Graco Warranty

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Graco Phone

Number

TO PLACE AN ORDER

, contact your Graco

distributor, or call this number to identify the distributor
closest to you: 

1–800–533–9655 Toll Free

Technical Data

Electronic Meter

Flow range*

0.12 to 12.0 gpm

. . . . . . . . . . . . . . . . . . . . . 

0.456 to 45.6 lpm

Maximum operating pressure

1500 psi (105 bar)

. . . . . 

Weight (bare meter)

1.9 lb (0.95 kg)

. . . . . . . . . . . . . . . . 

Units of measurement

Factory-set in quarts.

. . . . . . . . . 

Display shows quantity in 0.01 increments

up to 199.99 gallons, quarts, or pints.

Totalizes in gallons or liters up to 19,999 units.

Inlet and outlet

1/2 npt, non-directional flow

. . . . . . . . . . 

Operating temperature range

–4

_

 F to 130

_

 F

. . . . . . . 

(–20

_

 C to 55

_

 C)

Storage temperature range

–40

_

 F to 140

_

 F

. . . . . . . . 

(–40

_

 C to 60

_

 C)

Battery specifications 

Rated discharge current

100 microamps

. . . . . . . . . . 

Rated capacity

1.0 amp hour

. . . . . . . . . . . . . . . . . . . . 

Maximum continuous discharge
  current

1.0 milliamp

. . . . . . . . . . . . . . . . . . . . . . . . . . . 

Wetted parts

aluminum, nickel, bronze,

. . . . . . . . . . . . . 

stainless steel #304, carbon steel,

cast ALNICO 8, nitrile rubber

Dispense Valve

Flow capability 

12.0 gpm (45 lpm)

. . . . . . . . . . . . . . . . . 

at 50 psi (3.5 bar) pressure loss

using hydraulic fluid

Maximum operating pressure

1500 psi (103 bar)

. . . . . 

Weight (without meter)

4 lb (1.8 kg)

. . . . . . . . . . . . . . . . 

Inlet and outlet

1/2 npt

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Wetted parts

aluminum, carbon steel,

. . . . . . . . . . . . . . . 

copper, polyurethane, nitrile rubber

*

Tested in No. 10 motor oil.  Flow rates vary with fluid
pressure and viscosity.

Summary of Contents for 222441

Page 1: ...cap 222441 For Oil includes Hi Flow nozzle Meter is factory set in quarts Measures in liters 222571 For Oil includes cap 222541 For Oil includes Hi Flow nozzle These products contain P N 222560 which...

Page 2: ...arts Display shows quantity in 0 01 increments up to 199 99 gallons quarts or pints Totalizes in gallons or liters up to 19 999 units Inlet and outlet 1 2 npt non directional flow Operating temperatur...

Page 3: ...pressure of this component D Use fluids and solvents that are compatible with the equipment wetted parts Refer to the Technical Data section of all equipment manuals Read the fluid and solvent manufac...

Page 4: ...t of the body D Do not put your hand or fingers over the end of the dispensing valve D Do not stop or deflect leaks with your hand body glove or rag D Use only extensions and no drip tips that are des...

Page 5: ...l is shown in gallons for the gallon quart pint meter and in liters for liter meter The meter can accumulate a running total of up to 19999 gallons or liters dispensed before returning to zero See Fig...

Page 6: ...d close the nozzle by screwing the knurled sleeve fully counterclockwise See Fig 5 For electronic metered valves press the RESET key pad on the meter to clear it before the next dispense cycle See Fig...

Page 7: ...ave the drain valve open until you have com pleted repairs and are ready to pressurize the sys tem NOTE Before you check or repair the meter be sure all other valves controls and the pump are operatin...

Page 8: ...e pressure always follow the Pressure Relief Procedure on page 7 2 Attach the disposable grounding wrist strap to your wrist Connect the adhesive backed copper foil at the other end to any convenient...

Page 9: ...l to 19 to 21 ft lb 26 to 28 N m Adjust the Valve Loosen the locknut 8 Turn the adjusting screw 9 in or out as needed To stop the fluid flow all of the pres sure of the screw 9 against the push rod 20...

Page 10: ...er 5 8in 16 mm dia 3 8 in 9 5 mm long 1 4 150451 GASKET copper 1 5 155500 O RING nitrile rubber 1 6 156401 O RING nitrile rubber 2 7 157974 WASHER special 1 8 158213 NUT lock 3 8 24 1 9 158214 SCREW s...

Page 11: ...ef No Part No Description Qty 1 224304 VALVE 1 2 186660 SPOUT 1 4 223920 HI FLOW NOZZLE see parts below 1 5 235880 METER gallon quart pint 1 6 158491 NIPPLE 1 7 172479 TAG WARNING not shown 1 With Lit...

Page 12: ...terials not supplied by Graco This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claim If the clai...