6
307-712
TYPICAL INSTALLATION
KEY
A
Air Supply Shut-off Valve (bleed-type)
B
Air & Water Separator
C
Ball Valve
D
Air Line Lubricator
E
Air Regulator
F
Pump
G
Fluid Filter
H
Drain Valve
J
Pump Ground Wire
K
Air Filter (40 micron)
L
Fluid Regulator
N
ES Automatic Gun
P
Normally Closed, 3-Way Air Solenoid
Valve or 3-Way Manual Valve
Q
Exhaust Hose
NON–HAZARDOUS AREA
HAZARDOUS AREA
WARNING
SIGN
B
K
F
A
E
D
H
G
C
E
A
N
Power Supply Must Be Interlocked
With Spray Booth Exhaust Fan.
J
A
L
Turbine Air
Atom. Air
Cyl. Air
Fluid Line
Electric Box
J
Q
P
Opt. Remote F
an Air
J
Main Air Line
The Typical Installation shown above is only a guide for
selecting and installing electrostatic air spray systems. It
is not an actual system design. The particular type and
size system for your operation must be custom designed
for your needs. For assistance in designing a system,
contact your Graco representative.
WARNING
Installing and servicing this equipment requires ac-
cess to parts which may cause electric shock or other
serious bodily injury if work is not performed properly.
Do not install or service this equipment unless
you are trained and qualified.
Be sure your installation complies with National,
State and Local codes for the installation of electrical
apparatus in a Class 1, Group D, Divisions 1 and 2
Hazardous Location.
Warning Signs
A warning sign in English and one in Spanish is supplied
with the gun. Mount warning signs in the spray area
where they can easily be seen and read by all operators.
This sign is also available in French and German. See the
ACCESSORIES section to order.
Ventilate the Spray Booth
WARNING
To prevent hazardous concentrations of toxic and/
or flammable vapors, spray only in a properly ven-
tilated spray booth. Never operate the spray gun
unless ventilation fans are operating. The air
supply to the gun must be electrically interlocked
with the ventilators to prevent operation of the
power supply unless ventilating fans are running.
Check and follow all of the National, State and Lo-
cal codes regarding air exhaust velocity require-
ments.
Check and follow all local safety and fire codes and
OSHA standard 1910–107(b)(5)(i).
NOTE: High velocity air exhaust will decrease the oper-
ating efficiency of the electrostatic system. The
minimum allowable air exhaust velocity is 19 lin-
ear meters/minute (60 ft/min).