Warnings

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Installation

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Operation

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Service

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Parts

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Accessories

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Graco Standard Warranty

10

. . . . . . . . . . . . . . . . . . . . . . 

Graco Information

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Symbols

Warning Symbol

WARNING

This symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.

Caution Symbol

CAUTION

This symbol alerts you to the possibility of damage to
or destruction of equipment if you do not follow the
corresponding instructions.

NOTE: The following warning applies only to Models 214018, 208250, 214019, & 210097, which contain aluminum
housings.

WARNING

Hazard of Using Fluids Containing Halogenated Hydrocarbons

Never use 1,1,1–trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids contain-
ing such solvents in the models listed in the not above. Such use could result in a serious chemical reaction,
with the possibility of explosion, which could cause death, serious injury and/or substantial property damage.

Consult you fluid suppliers to ensure that the fluids being used are compatible with aluminum parts.

Installation

Connect the Fluid Hose

Regulators or Circulating Adapters:
Connect the fluid hoses to the 1/4 npsm(m) inlet and
return fittings.

Straight Adapter: 
Connect a hose to the 3/8 npsm(m) inlet fitting.

Connect the Regulator or Adapter to the Gun

Model 223622: 
Screw the regulator union adapter onto the gun fluid
inlet.

Models with Twist-lock Couplers: 
Screw the coupler stem onto the gun inlet. Connect the
twist-lock couplers by lining up the coupler slots with
the pins on the stem, pushing the coupler onto the
stem, then twisting the coupler clockwise to lock it.

Models with Slip-ring Couplers: 
Pull the slip ring back as you push the coupler onto the
stem.

Summary of Contents for 208082

Page 1: ...sure Part No s 223625 and 223628 300 psi 2 1 MPa 21 bar Maximum Inbound Fluid Pressure TWIST LOCK SLIP RING UNION ADAPTER TWIST LOCK 223627 1 0 oz 208085 1 5 oz 223628 1 3 oz 223621 7 0 oz 208082 7 5...

Page 2: ...e models listed in the not above Such use could result in a serious chemical reaction with the possibility of explosion which could cause death serious injury and or substantial property damage Consul...

Page 3: ...e to the gun and trigger the gun to relieve fluid pressure in the hoses before disconnecting hoses from the regulator or adapter To Clean or Service the Regulator 1 Relieve the air and fluid pressures...

Page 4: ...seal acetal 1 24 186202 HOUSING coupler stainless steel 1 25 168890 SPRING compression 1 26 168888 VALVE SEAT acetal 1 27 168889 RETAINER seat 1 28 168891 SPRING compression 1 29 208088 SLIP RING COUP...

Page 5: ...A Includes items 1 18 35 36 Model 223623 Series A Includes items 1 18 20 24 25 37 40 COMMON PARTS FOR REGULATORS 2 3 1n 20 24 23 21 22 19 25 27 26 n19 28 31n 32 33 30 34 36 35n 20 24 39 37 40 41n 25 1...

Page 6: ...Description Qty 3 186203 COUPLING NUT stainless steel 1 4 186202 HOUSING coupler stainless steel 1 7 168890 SPRING compression 1 9 101947 BALL stainless steel 0 375 9 5 mm dia 1 10 104338 SEAL spring...

Page 7: ...G compression 1 8 169472 HOUSING straight adapter 1 9n 101947 BALL stainless steel 0 375 9 5 mm dia 1 14 168888 VALVE SEAT acetal 1 15 168889 RETAINER seat 1 16 168891 SPRING compression 1 17 208088 S...

Page 8: ...03 COUPLING NUT stainless steel 1 5 186202 HOUSING coupler stainless steel 1 7 181578 HOUSING coupler 1 8 168890 SPRING compression 1 9 169473 HOUSING circulating adapter 1 10 101947 BALL stainless st...

Page 9: ...ly PTFE Diaphragm 185028 with PET Backing Diaphragm 168880 Use when regulator must be submersed in a solvent incompatible with the buna n backing of the standard diaphragm 178321 K The PTFE diaphragm...