15W034 Beacon Tower Kit Installation 

2

313542F

15W034 Beacon Tower Kit 
Installation

NOTE: Kit 15W034 is for ProMix 2KS manual systems.

1.

Feed wires through the hole in adapter (A) and 
secure the adapter to beacon (1) with set screws.

2.

Remove the 3/4 in. (19 mm) knockout on top of the 
EasyKey. Feed the wires through the hole and 
secure the beacon (1) with the jam nut (N) and 
washer on the inside of the box. See F

IG

. 1.

3.

Install the din rail (7) with two screws (8). Install the 
header (5) on the din rail and connect the cable (4) 
to J5 on the EasyKey display board. See F

IG

. 4. 

4.

Connect yellow and gray wires from beacon to the 
power terminal. See F

IG

. 2.

5.

Connect orange, brown, and red wires to header (5) 
pins 3, 4, and 5. See F

IG

. 6 on page 6.

6.

To enable the optional audible alarm, connect pur-
ple wire to pin 3 on header (5). See F

IG

. 6 on page 

6. When enabled, it will sound for all system alarms.

7.

When beacon wiring is completed, insulate the end 
of each unused lead wire with insulation tape.

Beacon Signals

NOTE: See the ProMix 2KS operation manual for details 
of the specific alarms.

F

IG

. 1: Install Beacon on EasyKey

TI14040b

1

N

A

F

IG

. 2: Power Terminal Connections

Flashing 
Signal/
Audible

Description

Amber

A system warning is active; verify alarm.

Red

A potlife alarm exists. 
System goes to Standby.

Green

Not used.

Audible

A system warning is active; verify alarm.

INPUT A

C

OUTPUT DC

DC

OK

+

-

-

N (-)
  NC
  NC
L (+)

TI14041a

Gray (+24V)

Yellow 
(Common)

Summary of Contents for 15W034

Page 1: ... and mounting hardware Important Safety Instructions Read all warnings and instructions in your propor tioner installation operation and repair manuals Save these instructions TI14039a 122193 Beacon Tower Shown Related Manuals Manual Description 312775 ProMix 2KS Manual System Installation 312776 ProMix 2KS Manual Systems Operation 312778 ProMix 2KS Automatic System Installation 312779 ProMix 2KS ...

Page 2: ...n to the power terminal See FIG 2 5 Connect orange brown and red wires to header 5 pins 3 4 and 5 See FIG 6 on page 6 6 To enable the optional audible alarm connect pur ple wire to pin 3 on header 5 See FIG 6 on page 6 When enabled it will sound for all system alarms 7 When beacon wiring is completed insulate the end of each unused lead wire with insulation tape Beacon Signals NOTE See the ProMix ...

Page 3: ... it will sound for all system alarms 6 When beacon wiring is completed insulate the end of each unused lead wire with insulation tape Install on a ProMix 2KE 1 Disconnect the existing alarm from pins 1 and 2 on the terminal strip See FIG 3 2 Mount the beacon near the control box and secure with the jam nut N and washer Feed the wires into the box 3 Connect the gray wire from the beacon to pin 12 o...

Page 4: ...122193 Beacon Tower Installation 4 313542F ...

Page 5: ... terminal female 3 3 CONNECTOR 10 position 1 4 WIRE HARNESS 3 conductor with shield 24 in 0 6 m 1 5 HEADER 5 position din rail mount 1 6 CONNECTOR 5 position 1 7 DIN RAIL 1 8 SCREW machine 6 32 x 1 4 in 6 mm 2 FIG 4 15W034 Beacon Kit Parts INPUT AC OUTPUT DC TI14039a TI14038a 2 3 4 6 5 1 Pin 1 Pin 2 Last Pin Mount din rail 7 in these holes using two screws 8 TI12578a ...

Page 6: ...raco com patents TO PLACE AN ORDER contact your Graco distributor or call to identify the nearest distributor Phone 612 623 6921 or Toll Free 1 800 328 0211 Fax 612 378 3505 FIG 5 122193 Beacon Tower Wiring Diagram FIG 6 15W034 Beacon Tower Kit Wiring Diagram 1 2 3 4 5 6 7 8 9 10 FLOW CONTROL CAL BLK GUNTRIGGER WHT DIGITAL IN COMMON RED REMOTE STOP GRN ALARM RESET BRN ALARM OUTPUT BLU DIGITAL OUTP...

Reviews: