Pressure Relief Procedure
2
311616D
Pressure Relief
Procedure
1.
Set START/STOP switch to STOP.
2.
Push in SECURE DISABLE switch.
3.
Open the back pressure regulator and all fluid drain
valves in the system, having a waste container
ready to catch drainage. Leave open until you are
ready to pressurize system again.
4.
Check that pressure gauges on fluid supply and
return lines read zero. If gauges do not read zero,
determine cause and carefully relieve pressure by
VERY SLOWLY loosening a fitting. Clear obstruc-
tion before pressurizing system again.
Kit Parts
NOTE: Slider Bearing Kit 15H882 includes parts to
rebuild both slider bearing assemblies. Parts included in
the kit are marked with an asterisk, for example (5*).
Use all the new parts in the kit.
Parts designated n/a are not available separately.
Kit Installation
Disassembly
1.
Jog the motor to bring the pump on the side being
repaired to the bottom of its stroke. This provides
access to the coupling nut (14).
2.
Relieve pressure, page 2.
3.
Shut off electrical power to the unit.
4.
Remove two screws (12) and the cover. F
shows the cover (32) on the stand side; the motor
side cover is (21).
System pressure can cause the pump to cycle unex-
pectedly, which could result in serious injury from
splashing or moving parts.
Ref.
No.
Part No. Description
Qty
5*
n/a
SCREW, cap, socket-head; 5/8-11
x 3 in. (76 mm)
4
8*
n/a
SLIDER BEARING
4
12*
116719 SCREW, 8-32 hex washer head
4
F
IG
. 1. Remove Coupling Nut
ti9223d
3
12
14
9
Place clean rag over slider cylinder (2).
Hold slider piston (9) flats with 3/4 in. wrench, and brace
against tie rod (3).
9
10
10
32
72
Summary of Contents for 15H882
Page 5: ...Kit Installation 311616D 5...