Installation 

2

309238E

Installation 

Installing the Oil Tank Monitor

NOTE: 

Although the Oil Tank Monitor is rated for a max-

imum air working pressure of 150 psi and has a recom-
mended operating pressure of 90 psi, Graco 
recommends using 50 psi pressure when used with 
Graco Diaphragm pumps.

NOTE:

 

If an air regulator is to be used, be sure that it is 

connected to the air inlet port of the oil level monitor. 
See Fig 1 Graco Used Oil Evacuation Installation Guide.

1.

Shut down system and relieve system pressure. Fol-
low the Pressure Relief Procedure found in the 

Pump Module Manual that initially came with your 
system. 

2.

Remove thread protector and discard.

3.

Connect float chain (A).

4.

Connect air supply to inlet port (B, F

IG

. 3).

F

IG

. 1

Reference only.
Parts are 
included in 
Kit 240684

Reference only.
Part no. 236265

1/4 NPT x 1/8 NPT
Nipple
User Supplied

Reference only.
Parts are included
in Kit 240684

WARNING

PRESSURIZED EQUIPMENT HAZARD

The equipment stays pressurized until pressure is 
manually relieved. To reduce the risk of serious injury 
from pressurized fluid, accidental spray, or splashing 
fluid, follow the pressure relief procedure provided in 
your pump instruction manual before servicing.

F

IG

. 2

Summary of Contents for 116229

Page 1: ...off Use with the Graco Used Oil Evac System Not intended for use in a caustic environment Part No 116229 150 psi 1 04 MPa _10 4 bar Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual and in the pump instruction man ual included with your system Save all instructions ...

Page 2: ...m pressure Fol low the Pressure Relief Procedure found in the Pump Module Manual that initially came with your system 2 Remove thread protector and discard 3 Connect float chain A 4 Connect air supply to inlet port B FIG 3 FIG 1 Reference only Parts are included in Kit 240684 Reference only Part no 236265 1 4 NPT x 1 8 NPT Nipple User Supplied Reference only Parts are included in Kit 240684 WARNIN...

Page 3: ...ply line to outlet port C FIG 3 NOTE Make sure internal air hoses are connected and there are no kinks 6 To verify operation a turn on main air supply the pump should start b Lift the float to shut off air supply and pump should stop FIG 3 C B ...

Page 4: ...25 bar Recommended air working pressure with Graco pump 50 psi 0 34 MPa 3 44 bar Materials of construction Air fittings Nickel plated brass Tubing Polyethylene Float Aluminum Case and cover ABS Plastic Other parts Aluminum and steel WARNING This product can expose you to chemicals known to the State of California to cause cancer and birth defects or other reproductive harm For more information go ...

Page 5: ...Technical Specifications 309238E 5 Dimensions ...

Page 6: ...rial or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty s...