HMI Operation
30
3A0261K
Valve Type
Only one of the three valve type options can be enabled
at any given time. This feature is enabled at the time of
build based on Valve Type and should not be manipu-
lated.
Enabling the Valve Type with a 1053 - 1 in. when a 1053
- 2 in. or 1093 is used will cause the improper maximum
shot size allowed by the mechanics of the valve.
Enabling the Valve Type with the 1053 - 2 in. when a
1053 - 1 in. will cause the Low Switch to be tripped and
will not allow the Valve to cycle.
Enabling the Valve Type with the 1053 - 2 in. when a
1093 is used will cause the improper maximum shot size
allowed by the mechanics of the valve.
Enabling the Valve Type with the 1093 when a 1053 - 1
in. or 1043 - 2 in. is used will cause the Low Switch or
PF44 to be tripped and will not allow the Valve to cycle.