Grace EC1500 User Manual Download Page 9

and 5 images from dual CIS model from a single insert direction. 

3.5.2

 

Move the cursor and selecting ‘Save MT’ will generate a .bin format file.   

3.5.3

 

Move the cursor and select ‘Save OCR’ will generate a file for OCR processing purpose. 

 

4.

 

Detections 

This  counter  incorporates  various  detections  including  UV(ultraviolet),  MG(magnetic),  MT(magnetic 
thread), Reflected IR mapping, and Penetrating IR mapping.   
 

5.

 

Maintenance and troubleshooting 

After start, the machine will go on self-check automatically. If preset window show the following error 
code, generally speaking, it is because of dust on the surface or sensor blocked by notes. So please clear 
the dust on the surface of sensor with brush or soft cloth, or take the notes away. Then restart the 
machine. 

Error code   

Trouble position 

E1

 

Bill UV sensor error

 

E2

 

Bill double error 

 

E3

 

Chain notes error

 

E4

 

Half notes error

 

E10

 

Bill CIS sensor signal lose

 

E11

 

Denomination error 

E12

 

Bill denomination error

 

E13

 

Bill facing recognize error

 

E14

 

Bill size recognize error

 

E15

 

Bill towards recognize error

 

E20

 

MT error

 

E21

 

MG1 error

 

E22

 

MG2 error

 

E23

 

MG3 error

 

E24

 

MG4 error

 

E30

 

IR transmission area 1 error

 

E31

 

IR transmission area 2 error

 

E32

 

IR transmission area 3 error

 

E33

 

IR transmission area 4 error

 

E34 

IR transmission area 5 error

 

E35 

IR transmission area 6 error

 

E36 

IR transmission area 7 error

 

E37 

IR transmission area 8 error

 

E38 

IR reflect area 1 error

 

Summary of Contents for EC1500

Page 1: ...Multi Currency Value Counter EC1500 USER MANUAL ...

Page 2: ...1 About this value counter Thank you for choosing this professional multi currency value counter based on CIS sensor We hope you enjoy using it This professional counter features its unique feeding mechanism and best performance of counting and detecting your banknotes 1 2 Box Content The box includes 1 unit of value counter 1 piece of AC power cord 1 copy of user manual and 1 piece of customer di...

Page 3: ...mode Button The default function is to move the cursor left When in batch setting mode it choose the number digits Button The default function is to move the cursor right When in batch setting mode it choose the number digits And this button also support to get in the setting menu when in the main interface Button The default function is to move cursor downwards adjust number magnitude in batch se...

Page 4: ...rating Working Environment 10 60 Stocking Ambient Humidity 20 90 no condensation Connection Port USB RS232 LAN 2 Operation Modes 2 1 CNT mode Press button MODE to select CNT mode In this mode you can switch on ADD or BATCH or ADD BATCH 2 2 SDC mode Press button MODE to select SDC mode This mode is to count a single denomination bill The system will take the first note as the benchmark and will sto...

Page 5: ...an use cursor to select next submenu and press ENTER button to confirm and use button CLEAR to quit 3 1 1 If you select to enter 1 Detection Level you will see the following interface You can use LEFT and RIGHT cursor buttons to select and UP and DOWN buttons to change the sensitivity levels The currency code in the right part is indicating for which currency you are operating Please do not change...

Page 6: ...enu you will be requested to input the password as well The default password is 0518 After the password you will see the following interface 3 2 1 If you enter Read Sensor Values you will see the following interface This interface is only for servicing purpose to see whether any sensor has a malfunction 3 2 2 If you enter CIS Calibration you will see the following interface to instruct you how to ...

Page 7: ...ill see the following interface This mode is to be used for production and professional servicing purpose 3 2 6 If you enter PCS counted and reset you will see the following interface This interface is to tell the total quantity of counted bills in this counter since last clearing to zero We provide a hidden setting for distributors to clear this number for after sales service 3 2 7 If you enter A...

Page 8: ... Setting under the main menu you will see the following interface 3 5 If you select to enter Save Image under the main menu you will see the following interface This mode is used to scan a banknote and output the data file into a USB flash drive 3 5 1 Press START button to go to Image saving mode It will generate 4 images from single CIS model ...

Page 9: ...sor blocked by notes So please clear the dust on the surface of sensor with brush or soft cloth or take the notes away Then restart the machine Error code Trouble position E1 Bill UV sensor error E2 Bill double error E3 Chain notes error E4 Half notes error E10 Bill CIS sensor signal lose E11 Denomination error E12 Bill denomination error E13 Bill facing recognize error E14 Bill size recognize err...

Page 10: ...nd person safety you must install good grounding when to use Safe pipe rated value is 2A not too much 6 2 Please turn off the machine and unplug the power cord when close every day To clean the sensors note feeding sensor note receiving sensor and counting sensors softly with brush If meet with trouble please ask for repairman to check and repair 6 3 The time between open and close should be over ...