background image

Multi-Currency Value Counter 

EC1500 

USER MANUAL 

 
 

 

 
 

 

Summary of Contents for EC1500

Page 1: ...Multi Currency Value Counter EC1500 USER MANUAL ...

Page 2: ...1 About this value counter Thank you for choosing this professional multi currency value counter based on CIS sensor We hope you enjoy using it This professional counter features its unique feeding mechanism and best performance of counting and detecting your banknotes 1 2 Box Content The box includes 1 unit of value counter 1 piece of AC power cord 1 copy of user manual and 1 piece of customer di...

Page 3: ...mode Button The default function is to move the cursor left When in batch setting mode it choose the number digits Button The default function is to move the cursor right When in batch setting mode it choose the number digits And this button also support to get in the setting menu when in the main interface Button The default function is to move cursor downwards adjust number magnitude in batch se...

Page 4: ...rating Working Environment 10 60 Stocking Ambient Humidity 20 90 no condensation Connection Port USB RS232 LAN 2 Operation Modes 2 1 CNT mode Press button MODE to select CNT mode In this mode you can switch on ADD or BATCH or ADD BATCH 2 2 SDC mode Press button MODE to select SDC mode This mode is to count a single denomination bill The system will take the first note as the benchmark and will sto...

Page 5: ...an use cursor to select next submenu and press ENTER button to confirm and use button CLEAR to quit 3 1 1 If you select to enter 1 Detection Level you will see the following interface You can use LEFT and RIGHT cursor buttons to select and UP and DOWN buttons to change the sensitivity levels The currency code in the right part is indicating for which currency you are operating Please do not change...

Page 6: ...enu you will be requested to input the password as well The default password is 0518 After the password you will see the following interface 3 2 1 If you enter Read Sensor Values you will see the following interface This interface is only for servicing purpose to see whether any sensor has a malfunction 3 2 2 If you enter CIS Calibration you will see the following interface to instruct you how to ...

Page 7: ...ill see the following interface This mode is to be used for production and professional servicing purpose 3 2 6 If you enter PCS counted and reset you will see the following interface This interface is to tell the total quantity of counted bills in this counter since last clearing to zero We provide a hidden setting for distributors to clear this number for after sales service 3 2 7 If you enter A...

Page 8: ... Setting under the main menu you will see the following interface 3 5 If you select to enter Save Image under the main menu you will see the following interface This mode is used to scan a banknote and output the data file into a USB flash drive 3 5 1 Press START button to go to Image saving mode It will generate 4 images from single CIS model ...

Page 9: ...sor blocked by notes So please clear the dust on the surface of sensor with brush or soft cloth or take the notes away Then restart the machine Error code Trouble position E1 Bill UV sensor error E2 Bill double error E3 Chain notes error E4 Half notes error E10 Bill CIS sensor signal lose E11 Denomination error E12 Bill denomination error E13 Bill facing recognize error E14 Bill size recognize err...

Page 10: ...nd person safety you must install good grounding when to use Safe pipe rated value is 2A not too much 6 2 Please turn off the machine and unplug the power cord when close every day To clean the sensors note feeding sensor note receiving sensor and counting sensors softly with brush If meet with trouble please ask for repairman to check and repair 6 3 The time between open and close should be over ...