Select Batch function 

 

Press the BH switch (or press the Mode button to switch to BH mode. Machine will be when 

it is Batch mode. 

 

LED (BH) indicator will be lighted.   

The input panel will be locked. 

 

After counting. Need to press the RESET to open the note holder 

 

The Batch number can range from l to 199. When the Batch number is set to 0 of 200 .the 

machine will not count. The machine comes into batch mode at the first time .the value is 0.   

 

When the preset number is set down .display will show it and this number can be used many 

times .Press the CL button to clear the previous number then input a new one. 

 

(4).Accumulation on Mode (AC) 

Select Accumulate ton function

 

Press the AC switch. Machine will be set to the ACCUMULATLON mode and AC indicator 

will be lighted.   

When it is in Accumulation mode 

 

CHECK function When counter is exactly 100. Machine will accumulate 100 into memory .

 

FREE function No matter any number is counted. Machine will accumulate it into memory 

 

BATCH function When counted number is equal to preset number machine will accumulate 

it into memory . 

To clear the ACCUMULATLON memory: 

Press the CL\C button. Machine will clear the ACCUMULATLON memory .Next time when 

we use the accumulation it will begin from 0. 

 

 

5

Select the counting speed mode   

The machine has four speeds 2.5 seconds\100 sheets, 3 seconds/100 sheets, 3.5 seconds/100 sheets, 

4 seconds/100 sheets   

 

Select the counting speed 

 

Press the SP button to select the speed: 2.5, 3,3.5,4 seconds/100 sheets 

Summary of Contents for GV-870

Page 1: ...Bundle Note Counting Machine GV 870 User Manual ...

Page 2: ... on the back and two sides of the unit for proper ventilation while installing 2 Do not expose the machine to the direct sunlight 3 Make sure to use the correct power supply 4 The operating environmental temperature ranges from 2 degree centigrade to 40 degree centigrade and the humidity is below 90 5 Altitude is below 1000m 6 It works in the condition where there is no inflammable and erodent mat...

Page 3: ...out 30 KGS 8 Note size 45mm 100mm 130mm 240mm 9 Control system Microcomputer of Dual CTU E Function Operation Procedures 1 Function 1 Check Mode You can check if the banknote is exactly 100 sheets 2 Free Mode You can count the banknote freely between 1 to 200 sheets 3 Batch Mode You can preset the banknote number and count them within range Number 0 and 200 can not be set 4 Accumulation Mode Accum...

Page 4: ...d CK indicator will be lighted When it is in Check mode LED CK indicator will be lighted The input panel will be locked After counting if counted total is not 100 sheets You need to press the RESET to open the holder otherwise the holder will open automatically 2 Free mode FR Within the range 200 max the machine can count the number what you preset After Counting the holder will open Select Free f...

Page 5: ...t Accumulate ton function Press the AC switch Machine will be set to the ACCUMULATLON mode and AC indicator will be lighted When it is in Accumulation mode CHECK function When counter is exactly 100 Machine will accumulate 100 into memory FREE function No matter any number is counted Machine will accumulate it into memory BATCH function When counted number is equal to preset number machine will ac...

Page 6: ...orized technicians We will not responsible for any damage caused by any unauthorized maintenance Contact supplier if the machine does not work properly 6 The guaranteed labels are on the main parts of machine please do not remove them or the product warranty or service will not be extended Banknote counting tips soft banknote low speed new banknote high speed Specification and information containe...

Page 7: ...Maintaining card examine date fault description maintaining employee trouble shooting examine date fault description maintaining employee trouble shooting ...

Reviews: