GPI LM50DB Instruction Manual Download Page 1

1

LM50DB / LM50DN (ELECTRONIC)

INSTRUCTION MANUAL

This meter is designed for in line use with Engine Oil & ATF
up to a maximum viscosity of SAE 140, Diesel & Water Gly-
col mixtures with a maximum water content of less than 50%.

Please read and retain this instruction manual to
assist you in the operation and maintenance of this
quality product.

GENERAL INFORMATION

This manual assists you in operating and maintaining your
new positive displacement flowmeter. The information
contained will help you ensure many years of dependable
performance and trouble free operation.

Please take a few moments to read through this manual before
installing and operating your new meter. If you experience
problems with this product, refer to the Maintenance and
Trouble Shooting sections of this manual.   If you require
further assistance please contact your local GPI
Distributor.

IMPORTANT INFORMATION

The GPI quality Positive displacement flowmeter has
incorporated the oval rotor principal into its design. This has
proven to be a highly reliable and highly
accurate method of measuring flow, providing exceptional
repeatability and high accuracy.

GPI  recommends, that  if you are using your meter as an in-
line application you should  install a filter
before the inlet of the meter. Contact your local GPI distributor
for further details.

INSTALLATION

2) Do not over tighten connections.

0002

OPERATION

LM50DB or LM50DN ELECTRONIC REGISTER

DISPLAY  BUTTON

Each press of the 

DISP

  button will allow you to scroll through

the meter options

Resetable Batch Total
Resetable Accumulative Total
Non Resetable Accumulative Total
Flowrate

RESET BUTTON

The 

RESET

 button allows you to reset the Batch Total or the

Resettable Acumulative Total to zero.

To reset either the Batch total or Resetable Acumulative total.
Press the 

DISP

 button to scroll  to either the Batch or  Resetable

total . When the required total is displayed. Press reset to zero
the totalizer.

FLOWRATE

This display option shows the flowrate of the fluid
passing through the meter.

IM083

0106

POSITIVE DISPLACEMENT FLOWMETERS

Summary of Contents for LM50DB

Page 1: ...er has incorporatedtheovalrotorprincipalintoitsdesign Thishas proven to be a highly reliable and highly accurate method of measuring flow providing exceptional repeatability and high accuracy GPI reco...

Page 2: ...nic computer module is non repairable The meter will need to be replaced if found to be damaged or faulty 1 Remove the 8 x philips head screws 1 from the meter cover 2 Remove the meter cover 2 and o r...

Page 3: ...oint 25 change non resetable accumulative total units 26 change non reset accumulative total decimal point 22 change batch total decimal point 27 change K factor 31 change flowrate units 32 change flo...

Page 4: ...1 1 decimal place 27 K FACTOR kFac 27 normal setting is 112 00 pulses b Press RESET 7 times kFac 27 will appear c Press and hold down RESET for 2 seconds program will appear To change the K factor pr...

Page 5: ...nds program will appear e Press RESET to select sleep setting no sleep sleep 5 f Press and hold down RESET until program disappears to accept setting f Press and hold down RESET until program disappea...

Page 6: ...1 DIAGNOSTICS dIA 7 diagnostic mode b Press the DISP button 5 times to reach dIA 7 c Press RESET dIA 71 will appear d Press and hold down RESET for 2 seconds Program will appear then all the segments...

Page 7: ...7 NOTES...