19
6. Factor
Press
【
F4
】
, pop up “atmosphere parameter setting” dialog box, after you input
temperature and atmospheric pressure, the PPM value will be calculated
automatically. when you press
【
F3
】
the EDM will return current EDM signal.
【
ESC
】
will quit signal show;
Another setting and config is operated by main menu — “parameter”
able 3-1 List of measurement condition setting
Item Options
1.Unitsoption
DMS* / GON / MIL;
Meter* / feet / feetinch;
℃
* /
℉
hPa* / mmHg
2.Unitsoption
(
dist
)
InterFeet* / US Feet
3.K option
0
﹡
/ 0.14 / 0.20
4.VA display
Zenith
﹡
/ Horizon 0 / V90 / slope
5.HA display
HAR
﹡
/ HAL
6.Auto Power off
Never* / 5min / 10min / 20min
7.Coord
N-E-Z
﹡
/ E-N-Z
8.EDM mode
Single* / repeat / Continue / Track
9.Mini readout
1"* / 5" / 10"
NOTE:
◆
Every first options with the symbol “
﹡
”are the factory setting.
Through the menu function , you can config the instrument. Press
【
MENU
】
,pop up main
menu then select
【
5
】
, the config menu is shown as follow:
You can config all instrument options according to your appliction
–
Parameter
–
1.Units(angle)
▲
2.Units(dist)
----------------------------
3.HA mode
4.VA mode
5.EDM mode
▼