GPI GM005 Instruction Manual Download Page 2

PLEASE READ THIS INFORMATION

CAREFULLY BEFORE USE!

Before use, confirm the fluid to be used

is compatible with the meter. Refer to

industry fluid compatibility charts or

consult your local representative for

advice.

To prevent damage from dirt or foreign

matter it is recommended that a Y or

Basket type 60 mesh strainer be

installed as close as possible to the

inlet side of the meter. Contact your

local representative  for advice. 

Note:

When a strainer is installed it

should be regularly inspected and

cleaned. Failure to keep the strainer

clean will dramatically effect flow

meter performance.

Note: 

To prevent damage caused by air

purge slowly fill the meter with fluid. 

To reduce pressure build up turn off the

pump at the end of each day.

Maintenance can be carried out to the

liquid crystal displays and pulse units

without removing or isolating the meter

from the line. When maintenance to

any other part of the meter is required,

the meter must be isolated and the line

pressure reduced.

The reed switch pulse unit can cause

inaccurate rate counts when used with

high speed counters. It is advised that a

debounce circuit be used. Contact your

meter distributor for further

information.

When fluid passes through the meter

the rotors turn, as shown below. The

magnets which are located in the rotors

will pass across the pulser circuit board

(containing either Reed switches or

Hall Effect sensors). A signal is

generated which is then sent by the

Pulse Circuit Board (PCB) to the

relevant LC display or receiving

instrument.

Operating Principle

Please take a few minutes to read

through this manual before installing

and operating your meter. Always

retain this manual for future reference.

If you have any problems with the

meter, refer to the maintenance and

trouble shooting sections of this

manual.

This manual contains connection and

operating instructions for the GM005

Series meters with Pulse outputs. For

models with an Liquid Crystal Display

an additional instruction manual is

supplied. If you need further assistance,

contact your local representative or

distributor for advice.

This Flow Meter has incorporated the

oval rotor principal into its design. This

has proven to be a reliable and highly

accurate method of measuring flow.

Exceptional repeatability and high

accuracy over a wide range of fluid

viscosities and flow rates are features of

the oval rotor design. With low

pressure drop and high pressure rating

oval rotor flow meters are suitable for

both gravity and pump (in line)

applications.

Flow meters are available in either

Aluminium or 316 Stainless Steel.

Standard rotors are made from PPS

(Polyphenylene Sulfide Resins) with

optional 316 Stainless Steel rotors

available for both Stainless steel and

Aluminium models.

GM005 Series Meters are available

with either;

* Pulse output

* Standard LC Display and Pulse

1

To the owner

Important Information