wit
h B
att
ery
Eje
cto
r
2
Hrs
*
1206I06033
- Compact charger with AC cord
- Charge 1 to 4 AA or AAA GP batteries
- Equipped with 4 individual charging channels
- Termination methods:
- Individual minus delta voltage (-dV)
- Individual temperature sensor
- Individual safety timer
- Over-temperature protection
- Primary and damaged batteries detection
- Easy check LED icons
- Battery ejector
Charger Features
Caution
1. Charge GP Nickel Metal Hydride (NiMH) batteries only. Do not
charge non-rechargeable batteries.
2. Do not charge other types of batteries, such as alkaline, carbon
zinc, lithium, rechargeable alkaline or any other unspecified
batteries, as they may leak or burst, causing personal injury and
damage.
3. Never use an extension cord or any attachment not recommended
by GP, as this may lead to a risk of fire, electric shock or personal
injury.
4. Unplug the charger from the outlet before attempting to clean
or when not in use.
5. Do not short circuit batteries.
6. Do not wet, incinerate or disassemble the charger and batteries.
7. For indoor and dry location use only. Do not expose the charger
to rain, snow or extreme conditions.
GPI International Ltd.
Gold Peak Building, 8/F., 30 Kwai Wing Road,
Kwai Chung, N.T., Hong Kong
Battery Icon
Power LED
Battery Ejector
Attention
1. It is normal for batteries to become warm during charging and
they will gradually cool down to room temperature after being
fully charged.
2. For best result, use GP Charger at room temperature
with good ventilation.
3. Charging time may vary based on different battery capacities.
(Refer to the Charging Time Table)
4. Remove batteries from an electrical device if it will not be used
for a long time.
5. If the performance of the batteries decreases substantially, it is
time to replace the batteries.
6. The batteries should be removed from the charger before they
are scrapped and disposed of properly.
7. If the supply cord is damaged, it must be replaced by a special
cord or assembly available from the manufacturer or its service
agent to avoid a hazard.
Charging Instructions
1. Charge 1 to 4 AA or AAA GP batteries in any combination.
Each charging slot can only charge 1 battery (either AA or AAA).
2. Connect the provided AC cord with the charger and plug it into
the power source (Fig.1). OR connect GP DC 12V car adaptor
to the charger and plug it into the cigarette lighter jack (Fig.2).
DC car adaptor is only included in select models.
3. Power LED will light up when power is connected.
4. Insert AA or AAA GP batteries into the charging slots
according to the polarity indications (+/-). Different contact plates for
AA and AAA GP batteries are set in the outer and inner part of
the charging slots respectively. (Fig.3) When inserting AAA
batteries into the charging slots, slant the batteries to ensure smooth
contact with the plates. (Fig.4)
5. Battery Icon will pulse slowly when charging is in process.
6. If alkaline, carbon zinc, lithium, rechargeable alkaline or damaged
batteries are mistakenly inserted into the charging slots, the
corresponding Battery Icon will blink fastly and the charger will
stop charging. All other Battery Icons will turn off.
7. If the charger does not work properly, all Battery Icons will turn off.
The Power LED will blink. The charger will stop charging.
8. Battery Icon will be solid on when battery is fully charged and
in trickle charge mode.
9. Once charging is complete, unplug the charger from the power
source and remove the batteries with the battery ejector (Fig.5).
Charging Time
GP
Instruction Manual
Charging Current (mA)
Trickle Charge
Current (mA)
Model
Input
Output
AA
AAA
AA
AAA
1-2
3
4
1-2
3
4
1-4
1-4
pcs pcs pcs pcs pcs pcs
pcs
pcs
Specifications
GP AR05GS
GP AR05BS
AC100-240V
50/60Hz
or DC 12V
1150 766 575 475 317 237.5 102.5
42.5
GP AR05US AC100-120V
60Hz
DC1.6V
1100 733 550 475 317 237.5
98
42.5
LED Indications (Refer to Fig. 6)
• Power connected
• GP battery inserted in
charger and charging in progress
• Wrong / damaged battery
inserted
• Full charge or trickle charge
Condition
Indication
• Green power LED on
• Orange battery icon slow pulsing
• Orange battery icon fast blinking
• Orange battery icon solid on
For best performance and optimal safety, charge GP
batteries with GP Charger/ GP
PowerBank
Fig. 1
Fig. 2
Fig. 5
Fig. 3
Fig. 6
Read the instruction manual thoroughly before use.
Keep the manual for future reference.
Type
Size
Typical
Charging Time (mins)
Capacity
1-2 pcs
3 pcs
4 pcs
AA
2050mAh
110
170
225
AAA
820mAh
115
170
225
Fig. 4