19
18
Unit 18 & 19, The Runway,
Christchurch,
Dorset. BH234FL.
gozneyovens.com
+44 (0)1425 204 996
w
e
t
GAS CLOSURE VENTILATION
OVEN SUPPORT STAND ENCLOSURE
It is important that the gas burner has sufficient ventilation to
operate correctly.
Gas ovens require clearance air spaces to ensure the gas
burner has adequate air intake. It is necessary to create an air
intake opening, measuring at least 500 mm x 500 mm, located
underneath the oven door/opening, as shown in the diagrams
above. Doing so will ensure that the air required for the gas
burner will be taken from the same atmospheric environment in
which the oven chamber opens. This is required for optimum
gas burner operation.
WARNING: Ensure the air intake opening remains clear from
obstruction at all times. When installing the oven outdoors, the
area around and beneath the oven must be kept clear of grass,
leaves and other combustible materials at ALL times.
Cladding to customers
design
Allow vent
In order for the gas burner to operate correctly, the external walls
of the oven support stand must be enclosed on all sides to shield
the gas burner from drafts or other atmospheric interruptions.
Support stand enclosure must be made entirely from non-
combustible materials.
Incorrect gas enclosure
Correct gas enclosure
PRE-INSTALL
VENTING
PRE-INSTALL
CLEARANCES
CEILING CLEARANCE
1000mm
50mm
Side profile of Classic oven.
Red area: minimum clearance
Front profile of traditional oven.
Red area: minimum clearance
WALL CLEARANCE
A minimum of 50mm clearance is required from all
sides of the outermost extremity of the oven walls.
If a façade or material is in contact with the oven, it
must be comprised of completely non-combustible
materials. When non-combustible materials are attached
to the oven, the above clearances must be measured
from the outside of those non-combustible materials.
Any materials 750mm to each side of the oven doorway
and above must be constructed of non-combustible
materials.
The oven stand should only be installed on a non-
combustible floor surface. The non-combustible floor
surface should extend a minimum of 1000mm out in front
of the oven and extend by a minimum of 750mm from either
side of the oven entrance.
When using a gas burning oven the space below the stand
must NEVER be used for storage. This space is required
for air intake of the gas burner. Not maintaining air
access to the burner is a serious risk and could void the
oven warranty.
A minimum clearance of 350mm from any combustible
material is required from the top of the oven. These
clearances apply over and above the oven core and
insulation materials, from the outer most extremity of the
oven’s final finished surface.
350mm
750mm
Summary of Contents for 100 Black Edition
Page 1: ...75 BLACK EDITION VERSION 1 2 DATED 10 05 2019 INSTALLATION MANUAL EUROPE...
Page 6: ...PRE INSTALL This section details how to correctly install a Gozney oven...
Page 11: ...0 0 Parts List Liste der Einzelteile Lista de partes Elenco delle parti Liste des pieces...
Page 14: ...1 0 Stand Stand Estar Stare in piedi Supporter...
Page 17: ...2 0 Arch and Floor Bogen und Boden Arco y piso Arco e pavimento Vo te et plancher...
Page 23: ...3 0 Dome and Flue Kuppel und Kamin C pula y chimenea Cupola e canna fumaria D me et conduit...
Page 37: ...Rendering Representaci n Rendering Le rendu 5 0 Rendering...
Page 42: ...WARRANTY This section explains the warranty associated to the oven...