Safety 

General

 

The machine is provided with safeguards where necessary. Make sure every person who comes in contact 

with the machine, or enters the area around it, wears adequate personal protection (overalls, safety 

glasses, ear protectors, helmet, steel-toed safety shoes etc.). Areas of the machine considered dangerous 

are marked with warning pictograms. 

If the machine remains easily accessible to persons, extra safety precautions (e.g. safeguards) must be 

installed. When safeguards are not possible, make sure clear instructions are given to people using the 

machine.  

 

 

Safety regulations 

  Read and observe the warnings and 

instructions given on stickers and labels on 

the Cleanflow. 

Do not ignore them. 

They are applied for your safety! 

  Goudsmit recommends a maximum lifting 

weight of 23 kg per person. 

For the heavier components use a lifting 

machine or ask a colleague to assist. 

  The activities described in this manual can 

only be done by trained, competent certified 

personnel. 

  Always observe the locally applicable safety 

and environmental regulations. 

  Apply protective cream to the body, if 

necessary. 

  Remain a safe distance from rotating and 

moving components. 

  To prevent the risk of fire, the Cleanflow and 

surrounding area must be free of flammable 

fluids. 

  Wear clean protective clothing, goggles and 

safety shoes when working on the Cleanflow. 

  Follow all safety and warning regulations 

provided in this manual! 

 

 

 

Lock Out Tag Out (LOTO) 

Lock Out Tag Out (LOTO) is an internationally agreed safety procedure to make sure that dangerous 

machines are properly shut off, and that they cannot be started again prior to the completion of 

maintenance or repair work. 

 

The Cleanflow is prepared for LOTO, Goudsmit recommends use of the LOTO procedure for every 

activity performed on the SRCP. 

 

This will reduce the risk of personal injuries. 

 

Summary of Contents for Easy Clean Cleanflow SECE Series

Page 1: ...The descriptions in this manual may differ from your version GOUDSMIT Magnetic Systems B V P O Box 18 5580 AA Waalre Petunialaan 19 5582 HA Waalre The Netherlands Tel 31 0 40 2213283 Internet www goudsmitmagnets com E mail info goudsmitmagnets com ...

Page 2: ... field 4 Identification plate 5 Removal of ferromagnetic particles in Easy Clean Cleanflows 6 Construction and functioning of Cleanflow magnet 7 Installation start up and servicing 8 The information we supply may only be used for service or operation of the product It may not be disclosed to any third parties without our prior written permission Our products and the data in our documentation may b...

Page 3: ...er components use a lifting machine or ask a colleague to assist The activities described in this manual can only be done by trained competent certified personnel Always observe the locally applicable safety and environmental regulations Apply protective cream to the body if necessary Remain a safe distance from rotating and moving components To prevent the risk of fire the Cleanflow and surroundi...

Page 4: ...ersonal items will be attracted if you are closer than 0 3 metres to a magnet Danger strong magnetic field People fitted with pacemakers should on no account enter the magnetic field within a radius of at least 1 metres Prohibited for people with pacemakers Credit cards chip cards computer disks tapes computer screens watches etc may be damaged or destroyed if they enter the magnetic field within ...

Page 5: ...5 Identification plate If you need to correspond about your device make a note of the numbers on the identification plate On smaller Cleanflows there may not be an identification plate ...

Page 6: ...the extractor will slide out of the front section automatically 4 Clean the ferromagnetic particles from the extractor with a clean soft brush 5 Dispose of ferromagnetic debris Use tray for sampling 6 Slide the extractor unit back into the housing and refasten 7 The magnet unit will slide back automatically back into the extractor unit 8 Resume product flow Pneumatic rods Contains the Magnets Fast...

Page 7: ...gh the pipe and around the magnets These capture ferromagnetic particles Features The manual pneumatic Cleanflows have a telescopic assembly Whereby the pneumatic components automatically move the magnet unit in and out of the front section of the extractor if it is pulled in or out of the housing Flange Guided extractor and magnet unit Pneumatically activated Fasteners ...

Page 8: ...mm free space underneath Start up Ensure that 1 The device has no damages or malfunctions Test the pneumatic bar operation with a paperclip It should react if the magnet is operated 2 All connections whether mechanical or pneumatic are made properly Servicing If the extractor or magnet bars are damaged or dented check that they still operate correctly Spare parts include the pneumatic bar magnet a...

Reviews: