![Gotting HG G-98830 Operating Manual Download Page 70](http://html1.mh-extra.com/html/gotting/hg-g-98830/hg-g-98830_operating-manual_2247547070.webp)
Operating Manual HG G-98830YA | English, Revision 02 | Date: 21.06.2021
70
Chapter 10 – Configuration of the System via the Service Interface
To end the output:
Press the key
.
Depending on which mode was stored, a system reset is triggered and the
antenna is back in the default state with the saved parameters.
You can save the CSV output e.g. with the help of the monitor program. Use Hyper
-
Terminal for this purpose, for example. You then proceed as follows:
Choose
Record text …
in the menu
Transfer
and enter a file name.
Save the file with the extension
.csv
, so that the spreadsheet can
automatically identify the file later.
After the file is recorded and closed under HyperTerminal:
Open the CSV file in a spreadsheet (e.g. Microsoft® Excel®, OpenOffice®
Calc®, …)
You can now format the data in chart form (see Figure 32) or save them as
native spreadsheet file for further distribution.
Figure 32
Importing CSV data into a spreadsheet (using Excel® as an example)
10.2.12 (Y) display Histogram
In the
(Y) display Histogram
menu, the voltages induced by a transponder in the scan
coils are displayed for the X and Y directions.
To switch from the main menu to the menu
(Y) display Histogram
:
Press the key
.
The following menu is shown:
Run through the text conversion wizards and specify in
step 2 that the data are separated by commas.
Open the CSV file in Excel by double-
clicking or insert it into an empty table
via „Data –> From Text“.
Select the 1st column "Code" as X value
and the 2nd column "Uref" as Y value and
create a line chart.