Data Interface CANopen®
English, Revision 06, Date: 12.07.2011
45
5.6.9
Producer Heartbeat Time
In case 0 is set, this function is deactivated.
5.6.10
Identity Object
5.6.11
Receive PRO_1 Parameter
Index
Sub Index
Name
Type
Attr.
Map
Default
Description
0x1017
00
Producer Heart-
beat Time
Unsigned 16
RW
No
0
Heartbeat time in
ms (approx.)
Table 23
CANopen® Directory: Producer Heartbeat Time
Index
Sub Index
Name
Type
Attr.
Map
Default
Description
0x1018
00
Identity Object
Unsigned 8
RO
No
0x04
Number of sub-
indexes
01
Vendor ID
Unsigned 32
RO
No
0x00000202
Manufacturer
number given
by CiA
02
Product Code
Unsigned 32
RO
No
0x00073840
HG Number
7384(0)
03
Revision
Unsigned 32
RO
No
0x00000100
Version 2.00
04
Serial Number
Unsigned 32
RO
No
9999999
Serial number
Table 24
CANopen® Directory: Identity Object
Index
Sub Index
Name
Type
Attr.
Map
Default
Description
0x1400
00
RxPDO_1
Parameter
Unsigned 8
RO
No
0x02
Number of sub-
indexes
01
COB ID
Unsigned 32
RW
No
0x40000200
+ Node-ID
RPDO_1 valid,
ID = 0x200 +
Node-ID
02
Transmis-
sion Type
Unsigned 8
RO
No
255
Asynchronous
event control
Table 25