Data Interface CANopen®
English, Revision 06, Date: 12.07.2011
44
5.6.6
Software Version
5.6.7
Save Parameter
By writing the signature ’save’ in ASCII Code (hex-Code: 0x65766173) onto subindex
1, the currently set parameters are permanently saved. A successful recording proce-
dure is acknowledged by an SDO (1. Byte = 0x60) after approx. 400 ms. During the
saving process it is not possible to transmit or receive CAN telegrams.
5.6.8
Restore Default Parameter
By writing the signature ’load’ in ASCII Code (hex-Code: 0x64616F6C) onto subindex
1, 2 or 3, the corresponding default parameters are loaded. A reset should be carried
out. In case of ’Restore All’, the Node ID is also set to 1 and the baud rate to 125
Kbaud.
Index
Sub Index
Name
Type
Attr.
Map
Default
Description
0x100A
00
Software Version
Visible_String
R0
No
„2.01“
Version number
Table 20
CANopen® Directory: Software Version
Index
Sub Index
Name
Type
Attr.
Map
Default
Description
0x1010
00
Save Parame-
ter
Unsigned 8
RO
No
0x01
number of sub
indexes
01
Save All
Unsigned 32
RW
No
0x00000001
Save All is
possible
Table 21
CANopen® Directory: Save Parameter
Index
Sub Index
Name
Type
Attr.
Map
Default
Description
0x1011
00
Restore
Parameter
Unsigned 8
RO
No
0x03
Number of sub-
indexes
01
Restore All
Unsigned 32
RW
No
0x00000001
Restore All is
enabled
02
Restore
Communi-
cation
Unsigned 32
RW
No
0x00000001
Restore Commu-
nication is possi-
ble
03
Restore
Manufacture
Unsigned 32
RW
No
0x00000001
Restore Manufac-
ture is possible
Table 22