Technical Data
English, Revision 03, Date: 07.02.2012
24
5
Technical Data
5.1
Identification Antenna HG 71451-A
Identification Antenna
Dimensions
Casing
Polycarbonat (PC)
Current consumption
160 mA
Operating Voltage Range
22 to 28 V (max. ripple 10 %)
Relative humidity at 25
o
C
95% (without condensation)
Weight
approx. 250 g
Protection class
IP 65
Max. Cable length
3 m
Connection
M12 circular connector 5-pin mounting plug
Elbow jack as accessories with different cable lengths
available (Standard 2 m)
Netto Code length
16 Bit
Nominal reading height
50 mm
Datafree area (D; see Figure 2 on page 6)
25 to 30 mm at nominal reading height
Field width (B; see Figure 2 on page 6)
25 mm at nominal reading height
Field width (L; see Figure 2 on page 6)
Casing length at nominal reading height
Crossing speed at nominal reading height
ZA (409 kHz)
YA (125 kHz)
-
with function positioning
accuracy: 1.5 m/s
-
without function positioning
accuracy: 2 m/s
-
with function posi-
tioning accuracy: 1
m/s
-
without function
positioning accu-
racy: 1.5 m/s
Repeat Accuracy
±2 mm at 0.5 m/s, noisefree environment and nominal
reading height
PosiPuls
24 V, 20 mA, current limited
Minimum distance between two reading
stations
1500 mm
Environmental temperature
0 to +50
o
C
Storage temperature
-20 to +70
o
C
Table 14