Gotop VT810 User Manual Download Page 7

 

#730#sampling interval (0 or 
15-65535 seconds)#number of 
pieces of data uploaded (0 -10)#user 
password## 

Set the timed data uploading function 
 
The factory-set uploading interval of the product is 30, and under this 
circumstance, the timed uploading function is turned on. The user can change 
the parameter according to his needs. 
 
e.g.: #730#20#4#0000## 
Description: “20” refers to point sampling every 20 seconds, and the 
positioning information will be uploaded after point sampling 4 times, that is, 
the uploading interval is 20*4=80 seconds. The user can change the 
parameter according to his needs. 
 
Note: The user can send the instruction #730#0#1#0000## to turn off the 
GPRS, so as to enter the power saving mode. 
 

#770#new password (4 digits) #old 
password (4 digits)## 

Change the user password 
 
Description: After the instruction is executed, the terminal will change the 
user password according to the user’s requirements. After successful setting, 
“&770&CONFIG OK&&” will be returned to the phone; if the password is 
wrong, “&770&PASSWORD ER&&” will be returned. 
 
e.g.: #770#1111#0000##. After the instruction is executed, the user 
password changes from 0000 to 1111. 
 

#801#letters or numbers (0-20 
digits)#user password## 

Change the user name 
 
Description: After the instruction is executed, the user name of the terminal 
under the GPRS mode will be set according to the requirements. After 
successful setting, “&801&CONFIG OK&&” will be returned to the phone; if 
the password is wrong, “&801&PASSWORD ER&&” will be returned. 
 
e.g.: #801#13900139000#0000## 
 

#802#APN (letters or numbers, 0-32 
digits)#login user name (letters or 
numbers, 0-20 digits)#login 
password (letters or numbers, 0-20 
digits)#user password## 

Set the APN 
 
Description: After the instruction is executed, the terminal APN under the 
GPRS mode will be set according to the requirements. After successful 
setting, “&802&CONFIG OK&&” will be returned to the phone; if the password 
is wrong, “&802&PASSWORD ER&&” will be returned. 
 
e.g. 1: #802#CMNET###0000##. After the instruction is executed, the 
terminal APN is CMNET, the login user name and password are blank. 
e.g. 2: #802#CCDLEN#Guest#Guest#0000##. After the instruction is 
executed, the APN is CCDLEN, the login user name is Guest and the login 
password is Guest. 
 
Note: The default APN of this product is CMNET. 
 
 

Summary of Contents for VT810

Page 1: ...install this product in a safe position of your vehicle Avoid dangerous or unsuitable positions otherwise harm to the driver or passengers may occur 3 This manual is just for your reference The conten...

Page 2: ...provide the positioning information supported by the GSM base station if the GPS satellite information is unavailable and the information about the latitude and longitude coordinates can be sent to t...

Page 3: ...a 25 25 2 Built in GSM antenna Built in Sensor G SENSOR Button Turn On Off Interface 2 pieces 4PIN Connector 2 pieces 2PIN Connector MIC External Relay External SOS Button External Power Input voltage...

Page 4: ...ering the security status if no vehicle vibration occurs within 20 minutes this equipment enters the sleep mode In the sleep mode this equipment neither locates nor uploads data but can send receive m...

Page 5: ...e phone and then the terminal will return a message about the location information with Google map link click the link by cell phone then the detailed position will show on Google map directly 8 Descr...

Page 6: ...e latitude and longitude will be returned 9880000 0000 is the factory set user password which can be changed Single location query a message about the specific location will be returned 5550000 0000 i...

Page 7: ...ill be returned e g 770 1111 0000 After the instruction is executed the user password changes from 0000 to 1111 801 letters or numbers 0 20 digits user password Change the user name Description After...