![Gotec SP32-01 Technical Information Download Page 5](http://html.mh-extra.com/html/gotec/sp32-01/sp32-01_technical-information_2247398005.webp)
- 5 -
GB
v
6.
Startup Procedure
After the pipe connections are installed the following rules must be taken
under consideration:
- Plug main power supply (position H) into socket. (230V/50-60Hz)
- LED display (position F) at the housing lights up by showing # 8.
- Close emergency shut-down valve (position J) to the appliance.
- Press start button (position G) briefly, pump starts and keeps running
on automatically.
- After reaching the upper switching level the suction pump switches off
automatically.
- Open emergency shut-down valve (position J) to the consuming
device.
- Consumer (position L) (e.g. stove, oil burner) take into operation.
Note:
In case of long runs of suction pipe, we recommend priming the
oil with a hand pump prior to the first startup procedure in order to avoid
a dry running operation of the pump unit. Dry running operation of the
pump unit is electronically limited to 5 min., afterwards the pump swit-
ches off automatically. After examination of the intake on tightness the
starting procedure must be repeated.
7.
LED-Display:
The SP32-01 is equipped with an LED-display which indicates the res-
pective operating condition.
Display:
0. Service tank is empty (e. g. after power failure)
1. Float is in the range oil reserve (close to empty)
2. Float is the range of switching on level
3. Float achieved upper switching off level (pump has switched off)
4. If the pump could not suck in oil (pump service tank is empty) a break-
down disconnection takes place after approx. 5 10 min.
5. If the pump did not reach level (2.) after 20min.
6. The oil level in the service tank is exceeded
7. Temperature sensor switches the pump off automatically at 60°C am-
bient temperature. (Detected inside the SP32-01), e.g. during overloa-
ding/overheating of the pump unit.
8. SP32-01 is under electrical tension
LED-Display off although the pump is powered: defect PCB or oil in
the safety pan
8. Maintenance
Before starting the maintenance work and dismounting the grey coloured
plastic cover (position E), always pull the main power supply plug! Ra-
pid-action valves (position J) close. Maintenance of the SP32-01 limits
itself only to the annual cleaning of the inserted fine filter (white plastic
filter cartridge) located in front of the electromagnetic piston pump. The
filter can be un-/re-screwed without tool by means of a coin.
9. Possible malfunctions and breakdown causes
The pump is additionally monitored over several control parameters.
At breakdown disconnection the following examinations at the entire
system and at the SP32-01 are to be made:
-
Is voltage applied and the LCD display is activated?
LED-display - off – Possible defect of PCB
LED display – off – Oil in safety pan
Caution: Please contact manufacturer immediately!
-Is oil present in the fuel oil tank? – Possible lack of oil?
LED-display 4 or 5
-Is the intake pipe tightened firmly?
LED-display 4 or 5
-Is the suction filter clogged?
LED-display 4 or 5
- Is the oil reservoir filled too high ?
LED- display 6
-Is the ambient temperature of the SP32-01 higher than 60°C?
LED-display 7
-Is the oil reservoir of the pump empty, i.g. power failure?
LED-display 0
-Is the flow rate of the piston pump built inside still sufficient?
LED-display 4 or 5
10. Warranty
The warranty period amounts to two years after delivery date of the oil
lifter. With a report on the defective equipment, plus proof of purchase
or installation (delivery note or copy invoice) is to be sent in for warranty
examination of the suppliers.
This guarantee applies to parts with material or manufacturing defects
and is limited to the replacement or repair of defective parts, without any
compensation or damages being claimed. Compensation or damages
can be claimed. We accept no responsibility for improper installation,
failure to comply with specifications or failure to maintain the product
11. Transportation reference
Prior to the dispatch of used devices they have to be emptied comple-
tely! Transport damages by fuel oil leakage will be at the cost of the
sender!
12. Performance Diagram
30
25
20
15
10
5
0
Suction height [m]
Filter
Power loss : for 10m horizontally, calculate a loss equivalent to 1m
vertical or 0.1 bar
Examples:
With a suction height of 4m and a horizontal distance of 40m the flow
rate will be approx. 12l/h.
or:
With a suction height of 4m and a horizontal distance of 10m the flow
rate will be approx. 18l/h.
13. Warning
The SP32 01 should be handled carefully. installation and servicing must
be performed by trained/authorised expert only and must confir with the
Pipe length
10 m
20 m
30 m
40 m
Flo
w
ra
te