Startup Procedure

 

After the pipe connections are installed the following rules must be taken 

under consideration:

 

- Plug main power supply (position H) into socket. (230V/50-60Hz)

 

- LED display (position F) at the housing lights up by showing # 8.

 

- Close emergency shut-down valve (position J) to the appliance.

 

- Press start button (position G) briefly, pump starts and keeps running

 

on automatically.

 

- After reaching the upper switching level the suction pump switches off

 

automatically.

 

- Open emergency shut-down valve (position J) to the consuming 

device.

 

- Consumer (position L) (e.g. stove, oil burner) take into operation.

 

 

Note: 

In case of long runs of suction pipe, we recommend priming the 

oil with a hand pump prior to the first startup procedure in order to avoid 

a dry running operation of the pump unit. Dry running operation of the 

pump unit is electronically limited to 5 min., afterwards the pump swit- 

ches off automatically. After examination of the intake on tightness the 

starting procedure must be repeated.

 

 

7. 

LED-Display:

 

 

The SP32-01 is equipped with an LED-display which indicates the res- 

pective operating condition.

 

 

Display:

 

0. Service tank is empty (e. g. after power failure)

 

1. Float is in the range oil reserve (close to empty)

 

2. Float is the range of switching on level

 

3. Float achieved upper switching off level (pump has switched off)

 

4. If the pump could not suck in oil (pump service tank is empty) a break- 

down disconnection takes place after approx. 5 10 min.

 

5. If the pump did not reach level (2.) after 20min.

 

6. The oil level in the service tank is exceeded

 

7. Temperature sensor switches the pump off automatically at 60°C am- 

bient temperature. (Detected inside the SP32-01), e.g. during overloa- 

ding/overheating of the pump unit.

 

8. SP32-01 is under electrical tension

 

 

LED-Display off although the pump is powered: defect PCB or oil in

 

the safety pan

 

 

 

8. Maintenance 

 

Before starting the maintenance work and dismounting the grey coloured 

plastic cover (position E), always pull the main power supply plug! Ra- 

pid-action valves (position J) close. Maintenance of the SP32-01 limits 

itself only to the annual cleaning of the inserted fine filter (white plastic 

filter cartridge) located in front of the electromagnetic piston pump. The 

filter can be un-/re-screwed without tool by means of a coin.

 

9. Possible malfunctions and breakdown causes 

The pump is additionally monitored over several control parameters. 

At breakdown disconnection the following examinations at the entire 

system and at the SP32-01 are to be made:

 

 

-

Is voltage applied and the LCD display is activated?

 

LED-display - off – Possible defect of PCB 

LED display – off – Oil in safety pan

 

Caution: Please contact manufacturer immediately!

 

-Is oil present in the fuel oil tank? – Possible lack of oil?

 

LED-display 4 or 5

 

-Is the intake pipe tightened firmly?

 

LED-display 4 or 5

 

-Is the suction filter clogged?

 

LED-display 4 or 5

 

- Is the oil reservoir filled too high ?

 

LED- display 6

 

-Is the ambient temperature of the SP32-01 higher than 60°C?

 

LED-display 7

 

-Is the oil reservoir of the pump empty, i.g. power failure?

 

LED-display 0

 

-Is the flow rate of the piston pump built inside still sufficient?

 

LED-display 4 or 5

 

 

10. Warranty 

The warranty period amounts to two years after delivery date of the oil 

lifter. With a report on the defective equipment, plus proof of purchase 

or installation (delivery note or copy invoice) is to be sent in for warranty 

examination of the suppliers.

 

This guarantee applies to parts with material or manufacturing defects 

and is limited to the replacement or repair of defective parts, without any 

compensation or damages being claimed. Compensation or damages 

can be claimed. We accept no responsibility for improper installation, 

failure to comply with specifications or failure to maintain the product

 

 

 

11. Transportation reference 

Prior to the dispatch of used devices they have to be emptied comple- 

tely! Transport damages by fuel oil leakage will be at the cost of the 

sender!

 

 

12. Performance Diagram 

 

30

 

 

25

 

 

20

 

 

15

 

 

10

 

 

5

 

 

0

 

Suction height [m]

 

 

 

 

 

 

 

 

Filter

 

 

Power loss : for 10m horizontally, calculate a loss equivalent to 1m 
vertical or 0.1 bar

 

Examples:

 

With a suction height of 4m and a horizontal distance of 40m the flow

 

rate will be approx. 12l/h. 

or:

 

With a suction height of 4m and a horizontal distance of 10m the flow

 

rate will be approx. 18l/h.

 

 

13. Warning 

The SP32 01 should be handled carefully. installation and servicing must 

be performed by trained/authorised expert only and must confir with the 

Pipe length

 

10 m

 

20  m

 

30  m

 

40  m

 

Flo

ra

te

 

 

Summary of Contents for SP32-01

Page 1: ...ion Instructions de montage et de mise en service Instructions for assembly and maintanance Montage und Wartungsanleitung À l usage des professionnels de la branche This information is only intended for the expert Diese Information ist nur für den Fachmann bestimmt ...

Page 2: ... Gerät ist nach EN 12514 2 EN 60335 1 und EN 55015 1 geprüft Die Pumpe verfügt über eine Ölmangelsicherung sowie eine Lecküber wachung für die Sicherheitsauffangwanne Zusätzliche zeitgesteuerte Kontrollsysteme überwachen die Funktion des Pumpwerkes 3 Wandbefestigung Die Pumpe wird mittels beiliegendem Befestigungsbügel mit Montage material waagerecht 2 an einer Wand befestigt Achten Sie darauf das...

Page 3: ...r dem Pumpenantrieb unter der Geräteabdeckhaube Der Filter kann ohne Werkzeug mittels eines Geld stücks ein und ausgeschraubt werden 9 Mögliche Störungen und Störursachen Die Pumpe wird im Betrieb über mehrere Kontrollparameter überwacht Bei Störabschaltung sind daher folgende Überprüfungen an der Anlage und am Gerät vorzunehmen Ist Spannung vorhanden leuchtet das LED Display LED Anzeige aus Öl in...

Page 4: ...ch pan In addition a time operated control systems supervise the function of the integrated piston pump 3 Wall Mounting The pump is fastened horizontally by means of enclosed attachment bracket with assembly material 2 to a wall Make sure that the two absorption rubber pieces are located under the plastic clamping latches on the back side of the pump system Pay attention to sufficient free space u...

Page 5: ...ilter cartridge located in front of the electromagnetic piston pump The filter can be un re screwed without tool by means of a coin 9 Possible malfunctions and breakdown causes The pump is additionally monitored over several control parameters At breakdown disconnection the following examinations at the entire system and at the SP32 01 are to be made Is voltage applied and the LCD display is activ...

Page 6: ... 6 GB re q ui re m e nt s of th e lo c al b ui ld in g re g ul at io n ...

Page 7: ...i votre citerne est équipée d un clapet anti retour ou que votre conduite d aspiration est équipée d un filtre veuillez prévoir une baisse des per formances de la pompe et une hauteur d aspiration plus faible que décrit dans le tableau ci dessus Le réservoir de la pompe étant à l air libre aucun système de purge n est nécessaire 3 Fixation de la pompe Toujours garder l accessibilité entre le plafo...

Page 8: ...Lorsque l affichage indique 6 il y a un surplus de mazout dans le bac principal Laisser le bac principal se vider automatiquement et si l alarme 6 revient au prochain cycle veuillez contacter votre installateur 7 Sécurité en cas de température élevée incendie surchauffe etc L alarme 7 s affiche lorsque la température ambiante est supérieure à 60 C Si cette inscription apparaît examiner d où provie...

Page 9: ...Mangold11 CH 1958 St Léonard Tel 41 0 27 205 72 05 info eckerle com www eckerle com info gotec ch www gotec ch Pour tout complément d information veuillez consulter notre site internet Für weitere Informationen besuchen Sie bitte unsere Internetseite unter For more informations visit our web site www gotec ch www eckerle com ...

Reviews: