Keyboard Adapter for PROFITEST 204

1

Applications

The PROFI-MFII Interface keyboard adapter allows for complete 
remote operation of the PROFITEST 204 test instrument, as well 
as convenient entry of comments for individual test points and 
descriptions for the system under test. All MF-II keyboard 
functions are made available via the interface.

Note

This adapter is only intended for use with 
PROFITEST 204 test instruments. Connection to other 
instrument types is not allowed and may result in 
damage to the connected instrument or the PROFI-MFII 
Interface. 
Only type MF-II multifunctional keyboards in accordance 
with DIN may be connected to the interface. The use of 
old PC, XT, or AT keyboards is not possible. These 
keyboards do not function together with the PROFI-MFII 
Interface, and may lead to malfunctioning, or damage to 
the adapter.

The interface works together with all commercially available, 
German language (QWERTZ) MF-II keyboards which support the 
02 code set. In case of doubt, use one of the following 
recommended keyboards:

Cherry G83-6105 German, 105 Key

Cherry G81-3000 German, 105 Key

Unikey KWD 205-D0 German

Suitable keyboards are available from ourselves or our 
distributors if required.

The device may not be used:

With open housing

If visible, external damage is apparent

If it no longer functions flawlessly

After excessive stress due to transport

After long periods of storage under unfavorable conditions
(e.g. humidity, dust)

After extreme overstressing

2

Functional Principle

The PROFI-MFII Interface is equipped with a microprocessor 
which detects and evaluates all of the so-called make and break 
codes which are generated by the interconnected keyboard. If 
the activation of an alphanumeric key is detected, the 
corresponding character is transmitted to the PROFITEST 204 
under consideration of shift and cap-lock key status. If the 
interface detects activation of any of the function keys from F1 to 
F8, the ESC key or the up and down scroll keys, a remote control 
command is transmitted to the test instrument.

3

Connection

Switch the test instrument off and disconnect or unplug it 
from the mains before connecting it to the interface.

Connect the PROFI-MFII Interface to the 9-pole socket at the 
test instrument with the included connector cable, and secure 
the plug to the test instrument with the screws.

Carefully insert the 6-pin PS/2 plug from your keyboard into 
the socket at the narrow side of the interface housing which 
faces away from the connector cable.

Reconnect the test instrument to the mains. The three 
indicator LEDs at your keyboard should flicker briefly, and the 
NUM LOCK LED should then light up continuously. If all three 
or none of the LEDs light up continuously, the keyboard has 
been incorrectly initialized. Repeat the connection procedure 
in this case, or use a different keyboard.

Note

The PROFI-MFII Interface is operative as soon as the test 
instrument has been connected to the mains and its fan 
is running. The function selector switch position is of no 
significance. 
If your keyboard is equipped with a 5-pin DIN connector, 
use a suitable plug adapter. Suitable adapters are 
available from computer hardware retailers.

4

Using the Keyboard

Use the keyboard in the same way you would with your PC. 
Please be aware of the following points:

The ESC key and function keys F1 through F8 are used for 
remote control:

ESC key

: MENU key

- F1

 key

: INFO / STORE keys

- F2

 key

: STORE + Comment (version AN+ or higher)

- F3

 key

: START key

- F4

 key

: MENU key

- F5

 key

: set selector switch to TEST

- F6

 key

: set selector switch to DATA

- F7

 key

: set selector switch to PRINTER

- F8

 key

: set selector switch to SETUP

Use the included template for quick and easy identification of 
the key functions.

The STORE + Comment function is equivalent to pressing 
and holding the STORE key after completion of a 
measurement with the test instrument. This allows for the 
entry of a description for the measuring point. This function is 
only supported by test instruments with software version 
“AN” or higher. Order a software update for your test 
instrument if the F2 key does not have any function.

The ENTER key must be used to conclude an alphanumeric 
entry (not the RETURN key). The RETURN key generates a 
carriage return and a new line within the entered description. 
The current entry line is exited by pressing the ENTER key.

The NUM LOCK function is permanently activated, and it 
cannot be deactivated.

The Ctrl, Alt and Alt Gr keys, as well as any available “Win-
dows” keys, are not functional. The Scroll Lock, Print and 
Pause keys are also non-functional. The 

 and 

 scroll keys 

have no function. The Insert, Home, Page Up, Page Down, 
Delete and End keys have no function. The F9 and F10 keys 
have no function.

The F11 and F12 keys can be used to enter the characters 
“[”and “]” respectively.