Clamp Multimeter METRACLIP 86
-to cycle through the
Ω
and diode test
modes and to return
to the continuity test
- to reset the measurement process for the “indicator of order
of rotation of the phases” function.
Long (>2 sec)
- to display the total three-phase power of a balanced system
(
is displayed).
- by pressing again, to return to display of the single-phase
power (
is off)
2.3
KEY
This key is used to backlight the display unit.
Successive
presses on
… serve
-to activate or de-activate the backlighting of the
screen
Remark:
the backlighting is switched off automatically at the end of 2 minutes.
2.4
KEY
2.4.1
In the normal mode
This key activates detection of the MAX, MIN, PEAK+ and PEAK- values of the
measurements made.
Max and Min are the extreme mean values in DC and the extreme RMS values in AC.
Peak+ is the maximum instantaneous peak and Peak- the minimum instantaneous
peak.
Remark :
in this mode, the "automatic switching off" function of the device is
automatically de-activated. The
symbol is displayed on the screen.