13.15 EL1 – Function Test for Extension
Cords
Attention!
!
This function permits an evaluation of
the continuity of the active conduc-
tors L(1, 2, 3) and N of an extension
cord. The PE conductor isn’t tested
in this case!
See corresponding single measurements for
the testing of R
PE
and R
INS
.
Note
See section 14 with regard to testing
extension cords per DIN VDE 0701-
0702, for which R
PE
and R
INS
are
measured.
Connecting the EL1 Adapter
➭
Connect the EL1 adapter to the P1 spe-
cial sockets at the test instrument.
➭
Connect the plug at the end of the ex-
tension cord to the test socket.
➭
Connect the coupling socket at the end
of the extension cord to the plug at the
EL1 adapter.
Connecting Test Adapters VL2E and AT3-IIIE
➭
Connection examples can be found in section
13.19.
Continuity test for L and N
Meas. Parameter
Test for
Measurement type
Continuity
L(1/2
/3)
, N
Short-c
ir
cuit
between
L(1/2
/3)
, N
Re
versed po
lar
ity /
cl
oc
kwise
phase sequence
EL1 adapter
X
X
—
EL1 adapter
(continuity only)
X
—
—
VL2E adapter
X
X
X
AT3-IIIE adapter
X
X
X
Select measuring function
1
EL1
Select parameters
2
Set parameters
3
Connect the DUT
4
EL1 adapter
P1
VL2E adapter
Start test
5
Save measured values to clipboard
6
Stop test
7
Save measurements under ID no.
9