background image

4

Gossen Metrawatt GmbH

Measurement results are displayed at the test 

instrument.

Note!

The AT3-III E test adapter is equipped with 

electronic error monitoring which discon

-

nects the device under test from the mains in 

the event of fault currents of greater than 

18 mA.

2

Safety Precautions

The test adapter has been manufactured and 

tested in accordance with the following regula

-

tions:
IEC 61010-1/DIN EN 61010-1/VDE 0411-1 “Reg

-

ulations for electronic testers and controllers, part 

1: Safety measures for electrical measuring instru

-

ments”
DIN VDE 0404 “Devices for technical safety test

-

ing of electrical equipment, parts 1 and 2.” 
EN 61326-1 product standard EMC requirements.
Safety is only assured for the user and the test 

adapter when used for its intended purpose in 

combination with the test instruments mentioned 

in chapter 1 "Applications".
In order to maintain flawless technical safety con

-

ditions, and to assure safe use, it is imperative that 

you read these operating instructions thoroughly 

and carefully before placing your test adapter into 

service, and that you follow all instructions con

-

tained herein.

Due to the fact that all tests performed with the AT3-

III E must be executed in combination with a test instru

-

ment mentioned in chapter 1 "Applications", you must 

also read the safety precautions and liability limitations 

included in the operating instructions for this instru

-

ment.

Observe the following safety precautions:

Attention!

!

If the red LED (10) remains lit even after 

the AT3-III E has been disconnected from 

the mains and connected once again, the 

test adapter is defective. If this is the case, 

the AT3-III E must be removed from service 

and repaired before it is used again.

In order to assure compliance with technical 

safety requirements, the AT3-III E test adapter 

should only be repaired by the manufacturer.

The AT3-III E must be disconnected from the 

mains and from the test instrument before it is 

opened.

Measurements within electrical systems are prohibited!

The test adapter’s 16 A CEE 3P+N+PE (16) 

plug may only be connected to 230/400 V 

50 Hz mains power. In order to avoid unde

-

sired shutdown of defective devices under 

test, the electrical circuit for the device under 

test should be separately fused.

Before connecting the AT3-III E to the mains, 

the test instrument must first be connected to 

the AT3-III E.

Attention!

!

Tests during which mains power is ap

-

plied may only be selected with the func

-

tion selector switch at the test instrument 

after safety class I devices under test 

have passed the protective conductor 

test. If the protective conductor is defec

-

tive (interruptions / reversed conductors), 

line voltage may be present at the hous

-

ing of a defective device under test, at the 

earthing contacts of the test plugs (4 – 7) 

and at the safety socket (15)!

For 

REASONS OF SAFETY

, the device under test 

must be turned off before switching to 

“MAINS” so that dangerous devices under 

test (e.g. a circular saw) can only be switched 

on intentionally.

Measurement with line voltage:

Exposed parts may conduct dangerous touch 

voltage during testing. Do not touch under 

any circumstances! Use a special cover in 

order to avoid touch contact.

Under certain circumstances, full mains dis

-

connection at the device side may not occur 

in the event of leakage current, or it may be 

inadequate to meet the requirements of a 

PRCD.

Work only at a protected workstation, i.e. use 

enhanced touch protection, use a 30 mA 

RCD and wear personal safety equipment 

(PSE).

Be prepared for the occurrence of unex

-

pected voltages at devices under test (e.g. 

due to charged capacitors).

Before connecting the device under test to 

the test adapter, subject it to a thorough 

VISUAL INSPECTION

 first. Damaged devices 

under test must be repaired prior to testing.

Only extension cables which have been 

plugged into the test outlets (1-4) at the test 

adapter may be connected to the device 

plugs (4- 7) at the test adapter.

Due to test adapter design in accordance with 

DIN VDE 0404, the “PE” contacts at the out

-

lets (1-4) are only connected to the mains pro

-

tective conductor when the test instrument 

has been set for testing with mains power.

Summary of Contents for AT3-III E

Page 1: ...ns AT3 III E Test Adapter For the Active and Passive Testing of Single and 3 Phase Electric Devices and Extension Cables in Combination with SECUTEST SECULIFE ST Test Instruments M7050 M7010 and M6930 3 349 155 37 17 3 21 ...

Page 2: ... Connectors for Test Instruments 12 Earthing contact outlet for power supply to test instru ments 13 Earthing contact plug with cable for insertion into the test socket at the test instrument 14 SECUTEST SIII SIII SIII H SECUTEST S2N S2N 10 N w SECULIFE ST ST HV port for insertion into sockets 2 and 3 at the test instrument SECUTEST PRO ST PRO SECULIFE ST BASE ST BASE25 port and or feature I01 for...

Page 3: ...peri odic testing per DIN VDE 0105 0701 0702 According to these regulations testing must be performed for protective conductor resistance insulation resistance equivalent leakage current residual current and contact current as well as for the absence of voltage depending upon the type of device under test The test adapter in combination with the test instru ment allows for the passive testing of p...

Page 4: ...electrical systems are prohibited The test adapter s 16 A CEE 3P N PE 16 plug may only be connected to 230 400 V 50 Hz mains power In order to avoid unde sired shutdown of defective devices under test the electrical circuit for the device under test should be separately fused Before connecting the AT3 III E to the mains the test instrument must first be connected to the AT3 III E Attention Tests d...

Page 5: ... test probe at the end of the probe cable of the test instrument into the socket 15 at the AT3 III E Connect the test adapter to 230 400 V mains power The test adapter now performs a self test If the tester is intact the red LED lights up briefly 4 Connecting a Device Under Test to the Test Adapter After the device under test has passed a visual inspection and before connecting it to the appro pri...

Page 6: ...ontact current is measured by means of residual current measurement for safety class II devices and safety class I devices with accessible con ductive parts which are not connected to the pro tective conductor Contact all accessible conduc tive parts at the device under test with the test probe at the end of the probe cable form the test instrument to this end These measurements must be performed ...

Page 7: ...erformed due to safety imped ances which have been integrated into the AT3 III E for testing 3 phase devices Figure 1 Connecting Single and 3 Phase Devices to the AT3 III E and the test instrument 230 400 V 50 Hz test adapter AT3 III E L3 L2 L1 SECUTEST 13 230 400 V 50 Hz test adapter AT3 III E L3 L2 L1 SECUTEST 13 COM V 1 SECUTEST SIII SIII SIII H SECUTEST S2N S2N 10 N w SECULIFE ST ST HV SECUTES...

Page 8: ... instrument Observe the following instructions when using the test instrument in combination with the AT3 III E The test probe at the end of the probe cable of the test instrument must first be connected to the respective socket 15 probe 1 to 4 of the associ ated plug at the AT3 III E In order to test only connect the plug and socket at the ends of the respective extension cable to be tested to th...

Page 9: ...e voltage Note When testing device cable connections socket 4 plug 4 polarity L N is not being checked Testing of 3 phase cables is the same except that it also includes an additional test for reversing of conductors L1 L2 L3 and N 3 phase cables have only passed testing for short circuits interruptions and reversed conduc tors clockwise rotation if the following test result appears Cable OK Messa...

Page 10: ... SECUTEST SIII SIII SIII H SECUTEST S2N S2N 10 N w SECULIFE ST ST HV Figure 4 Connecting Single Phase Extension Cables to the AT3 III E and the SECUTEST BASE BASE10 PRO SECUTEST ST BASE ST BASE10 ST PRO SECULIFE ST BASE ST BASE25 SECUTEST 1 2 2 1 230 400 V 50 Hz SECUTEST 3 4 4 4 3 230 V 50 Hz 1 ...

Page 11: ...ntact outlet If an excessively high value or interrup tion is indicated the protective conductor is interrupted The AT3 III E test adapter must be disconnected from the mains and the error in the electrical sys tem or the test adapter must be corrected The AT3 III E is equipped with a Trigger I n test key in order to allow for testing the included I n safety shutdown function at any time Performin...

Page 12: ...ith overload protec tion device In 16 A I2 1 45 In Electrical Safety Pollution degree 2 Safety Class I per DIN EN 61140 VDE 0140 1 Residual Current Shutdown 4 pole at IdN 14 6 mA ta 82 ms Device Fuses F0315 L250V 5 x 20 T32mA L 250 V DIN EN 60127 2 Electromagnetic Compatibility Intrinsic Uncertainty EN 61326 1 2013 class B Intrinsic Uncertainty EN 61326 2013 Mechanical Design Protection case IP40 ...

Page 13: ... make reference to the fact that the current status in this regard can be accessed on the Internet at www gossenmetrawatt com by entering the search term WEEE We identify our electrical and electronic devices in accordance with WEEE 2012 19 EU and ElektroG with the symbol shown to the right per DIN EN 50419 These devices may not be disposed with the trash Please contact our service department rega...

Page 14: ...is available on the Internet All trademarks registered trademarks logos product names and company names are the property of their respective owners Gossen Metrawatt GmbH Südwestpark 15 90449 Nürnberg Germany Phone 49 911 8602 111 Fax 49 911 8602 777 E Mail info gossenmetrawatt com www gossenmetrawatt com ...

Reviews: