background image

Specifications Information and Repair Parts Manual  

     

GCW Series

                                                           

GCWX-250-00

1

4/2021

Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate 

or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained in the General Operating 

Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or property damage! Retain instructions 

for future reference.  AMT reserves the right to discontinue any model or change specifications at any time without incurring any obligation.

©2021 AMT Pump Company, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.

Periodic maintenance and inspection is required on all pumps to ensure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure to do so 

voids warranty.

Aluminum General Purpose Pumps

Refer to pump manual 1808-633-00 for General Operating and Safety Instructions.

MAINTENANCE

 

To prevent accidental starting, always remove spark plug or disconnect 

and ground spark plug wire before attempting to service or remove any 

component.

MECHANICAL SEAL REPLACEMENT

Refer to figures 1, 2 and 3.

IMPORTANT:

 Always replace both seal seat and seal head (Ref. No. 9) to 

ensure proper mating of components!
1.  Unthread fasteners (Ref. No. 15) and remove casing (Ref. No. 13) and 

casing seal (Ref. No. 11).

2.  Remove volute (Ref. No. 10).
3.  Unscrew impeller fastener (Ref. No. 8) from motor shaft (fastener 

unscrews CCW looking at motor shaft).

NOTE:

 To prevent shaft from turning, remove shroud from engine and hold the 

flywheel in place. 

4.  Remove keyed impeller (Ref. No. 7) from motor shaft. Remove shims 

(Ref. No. 6) DO NOT LOSE SHIMS.

5.  Pry seal seat from recess of impeller. 
6.  Remove the adapter (Ref. No. 2) by unthreading fasteners (Ref. No. 4).
7.  Press seal head from rear of adapter.
8.  Clean adapter and impeller seal recesses and motor shaft. Make certain 

all surfaces are perfectly clean before installing new seal parts.

 

Handle seal parts with extreme caution and keep them clean. Do not 
touch polished seal faces with your hands. Do not apply lubricants on 
seal faces. This could cause a leak or premature seal failure.

9.  Apply a light coat of sealing compound to new seal head (See Figure 1) 

and press it into adapter recess using proper size tube or installation tool 

(see Figure 2). DO NOT press on carbon face. Install using flange only.

10.  Slide adapter onto motor mounting face. Attach with fasteners.
11.  Press new seal seat squarely into impeller recess. Avoid scratching 

polished surface.

NOTE:

 Use a soft, clean piece of cloth on seal seat face when installing to 

prevent marring.
12.  Replace any shim washers which may have been removed in disassembly 

(see SHIM ADJUSTMENT). Using key, put the impeller back in place.

13.  Install and tighten impeller screw.
14.  Reinstall volute and remount casing with fasteners.

NOTE: 

Volute gets placed inside casing before mounitng casing to adapter.

NOTE: 

Always  flush  pump  thoroughly  before  use  so  as  not  to  contaminate 

liquid being pumped. If impeller is replaced, seal assembly should also be 
replaced as seal is usually damaged in disassembly.

SHIM ADJUSTMENT

When installing a replacement impeller, it may be necessary to vary number of 

shims that will be required. This is done by adding 0.010” shim more than was 

removed and reassembling pump as follows: 

IMPORTANT: 

When clearance between impeller and volute exceeds 1/16” at 

face of impeller or 1/8” on outside diameter of impeller, it may be necessary to 

take corrective action.

1.  Ensure that casing is snugly in place and check shaft to make sure it is 

turning freely. If it turns freely, check to ensure that adapter and casing 

are seated firmly, compressing gasket where they meet. If they are not 

seated, tighten fasteners and recheck shaft for free turning. Tighten 

carefully, turning shaft while tightening. If shaft seizes before fasteners 

are completely tight, disassembly pump, remove one shim and repeat 

reassembly.

2.  If at any time during shim adjustment shaft does not turn free, or a metal-

to-metal rubbing can be heard or felt when turning shaft, repeat SHIM 

ADJUSTMENT procedure.

NOTE:

 Impeller must be as close as possible to volute in order to perform   

properly and retain suction capabilities.

DESCRIPTION

These pumps are engine driven, self-priming (to 20 ft. lift), portable units. Clog resistant impeller is capable of handling solids up to 1/4” diameter (2”=3/16” & 

3”=1/4”). For use with non-flammable, non-abrasive liquids compatible with pump component materials.

Figure 1 - Mechanical Seal Replacement

Figure 2 - Seal Installation Tool (Ref. No. 31)

Reviews: