background image

80 SERIES

OM−06362

MAINTENANCE & REPAIR

PAGE E − 3

PARTS LIST

Pump Model 82D1−1B20−X

(From S/N 1460627 Up)

If your pump serial number is followed by an N", your pump is 

NOT

 a standard production model. Contact

the Gorman-Rupp Company to verify part numbers.

ITEM 
NO.

PART NAME

PART 
NUMBER

MAT’L
CODE

QTY

1

PUMP END ASSY

82D1−(1B20−X) PPO

1

2

GROUND WIRE ASSEMBLY

13830

−−−

1

3

HEX HD CAPSCREW

B0402

15991

1

4

FLANGED HEX NUT

21765−310

−−−

1

5

T-TYPE LOCKWASHER

BL04

15991

1

6

ENGINE SHIELD

34331−036

15120

1

7

SPARK ARRESTER

29334−196

−−−

1

8

GUARD

34851−579

15120

1

9

RUBBER FOOT MOUNTING KIT

48152−607

−−−

1

10

HEX HD CAPSCREW

B0604

15991

2

11

FLANGED HEX NUT

21765−314

−−−

4

12

CAUTION PLATE

38816−146

13990

1

13

POP RIVET

11703D

13990

4

14

FLAT WASHER

KE06

15991

2

15

HEX HD CAPSCREW

B0608

15991

2

16

SPACER

31141−028

13000

2

17

ROLLOVER BASE

41583−361

24150

1

18

HATZ 1B20 ENGINE

29237−004

−−−

1

19

HAND CARRY DECAL

2613FT

−−−

2

20

FLAT WASHER

K06

15991

2

21

DISCHARGE STICKER

6588BJ

−−−

REF

22

WARNING DECAL

38816−256

−−−

REF

23

PRIMING STICKER

6588AH

−−−

REF

24

INSTRUCTION TAG

38817−085

−−−

REF

25

SUCTION STICKER

6588AG

−−−

REF

26

CAUTION DECAL

38816−341

−−−

1

27

ENGINE STARTUP TAG

38816−269

−−−

1

28

DIFFUSER DISC

29334−284

−−−

2

OPTIONAL:

WHEEL KIT

GRP30−52

−−−

1

Summary of Contents for 82D1-1B20-X

Page 1: ...N RUPP COMPANY D MANSFIELD OHIO www grpumps com GORMAN RUPP OF CANADA LIMITED D ST THOMAS ONTARIO CANADA Printed in U S A e2010 The Gorman Rupp Company INSTALLATION OPERATION AND MAINTENANCE MANUAL WI...

Page 2: ...NUMBER Please record your pump model and serial number in the spaces provided below Your Gorman Rupp distributor needs this information when you require parts or service Pump Model Serial Number The...

Page 3: ...tion Lines In Sumps PAGE B 3 Suction Line Positioning PAGE B 4 DISCHARGE LINES PAGE B 4 Siphoning PAGE B 4 Valves PAGE B 4 Bypass Lines PAGE B 5 GROUNDING PAGE B 5 OPERATION SECTION C PAGE C 1 PRIMING...

Page 4: ...oval PAGE E 6 Impeller Removal PAGE E 7 Seal Removal and Disassembly PAGE E 7 Seal Reassembly and Installation PAGE E 7 Impeller Installation And Adjustment PAGE E 8 Pump Casing Installation PAGE E 9...

Page 5: ...ssed in this manual are performed only after establishing that neither personal safety nor pump integrity are compromised by such prac tices If there are any questions regarding the pump or its applic...

Page 6: ...d non flam mable atmosphere free of combustible hazards It cannot be further modified without affecting performance and safe ty factors The shield and spark arrest ing modifications must be inspected...

Page 7: ...ternal combustion engine in an explosive atmosphere When operating internal combustion engines in an enclosed area make cer tain that exhaust fumes are piped to the outside These fumes contain carbon...

Page 8: ...c application Since the pressure supplied to the pump is critical to performance and safety be sure to limit the incoming pressure to 50 of the maximum permissible operating pressure as shown on the p...

Page 9: ...s close as practical to the liquid being pumped Level mount ing is essential for proper operation The pump may have to be supported or shimmed to provide for level operation or to eliminate vibra tion...

Page 10: ...is not furnished with the pump but is installed by the pump user make certain that the total area of the openings in the strainer is at least three or four times the cross section of the suction line...

Page 11: ...sired in the discharge line use a valve as large as the largest pipe to minimize friction losses Never install a throttling valve in a suction line A check valve in the discharge line is normally rec...

Page 12: ...by the liquid be ing pumped the unit must be grounded by attach ing the ground wire assembly to a ground rod In stall the ground rod in accordance with the Nation al Electrical Codes and all local co...

Page 13: ...ot prime when dry Extended operation of a dry pump will destroy the seal assembly Add liquid to the pump casing when 1 The pump is being put into service for the first time 2 The pump has not been use...

Page 14: ...ressure within the pump can cause parts being disen gaged to be ejected with great force al low the pump to cool before servicing Strainer Check If a suction strainer has been shipped with the pump or...

Page 15: ...ion In below freezing conditions drain the pump to prevent damage from freezing Also clean out any solids by flushing with a hose Operate the pump for approximately one minute this will remove any rem...

Page 16: ...quid to casing See PRIMING Suction check valve contaminated or damaged Clean or replace check valve Product vapor pressure too high Cool pump and product suction line Pump speed too slow Check engine...

Page 17: ...rdware Pump or drive not securely mounted Locate and eliminate source of air bubble Pumping entrained air Strainer clogged Check strainer and clean if neces sary Pump speed too high Check driver outpu...

Page 18: ...ly the same duty cycle the part can be checked and replaced before failure occurs reducing unscheduled down time For new applications a first inspection of wearing parts at 250 hours will give insight...

Page 19: ...lift Since pump installations are seldom identi cal your performance may be different due to such factors as viscosity specific gravity elevation tem perature and impeller trim If your pump serial nu...

Page 20: ...80 SERIES OM 06362 MAINTENANCE REPAIR PAGE E 2 PARTSPAGE ILLUSTRATION Figure 1 Pump Model 82D1 1B20 X...

Page 21: ...STER 29334 196 1 8 GUARD 34851 579 15120 1 9 RUBBER FOOT MOUNTING KIT 48152 607 1 10 HEX HD CAPSCREW B0604 15991 2 11 FLANGED HEX NUT 21765 314 4 12 CAUTION PLATE 38816 146 13990 1 13 POP RIVET 11703D...

Page 22: ...80 SERIES OM 06362 MAINTENANCE REPAIR PAGE E 4 ILLUSTRATION Figure 2 Pump Parts Only 82D1 1B20 X PPO...

Page 23: ...A 17090 1 13 IMPELLER 2912F 13040 1 14 CASING GASKET SET 504G 18000 1 15 WEAR PLATE ASSY 2643A 15990 1 16 STUD C0606 15991 8 17 NAME PLATE 38812 041 13990 1 18 DRIVE SCREW BM 04 03 17000 4 19 CASING D...

Page 24: ...engine used in this pump is not standard It has been modified for use in handling gasoline and other petroleum products in a well ventilated non flam mable atmosphere free of combustible hazards It c...

Page 25: ...spring centering washer 11 and seal spring Slide the shaft sleeve 8 and rotat ing portion of the seal off the engine shaft as a unit Apply oil to the shaft sleeve and work it up under the rubber bello...

Page 26: ...STATIONARY ELEMENT ROTATING BELLOWS IMPELLER SHIMS IMPELLER SPRING RETAINER ELEMENT CRANKSHAFT SEAL SLEEVE SPRING CENTERING WASHER DRIVE BAND Figure 3 Seal Assembly This seal is not designed for opera...

Page 27: ...learance of 008 to 015 inch 0 20 to 0 38 mm between the impeller and the wear plate is also rec ommended for maximum pump efficiency This clearance can be obtained by adding or removing gaskets in the...

Page 28: ...ENGINE MODIFICATIONS The engine used on this pump is not a standard commercial model It has been specially modified by Gorman Rupp for pumping gasoline and other petroleum products in a well ventilate...

Page 29: ...rpumps com warranty or call U S 419 755 1280 International 1 419 755 1352 For Canadian Warranty Information Please Visit www grcanada com warranty or call 519 631 2870 THE GORMAN RUPP COMPANY D MANSFI...

Reviews: