![GORMAN-RUPP PUMPS ULTRA V V4A60-B Installation, Operation, And Maintenance Manual With Parts List Download Page 38](http://html.mh-extra.com/html/gorman-rupp-pumps/ultra-v-v4a60-b/ultra-v-v4a60-b_installation-operation-and-maintenance-manual-with-parts-list_2246986038.webp)
OM-05816
ULTRA V SERIES
MAINTENANCE & REPAIR
PAGE E - 16
ounces (3,9 liters) of SAE No. 30 non‐detergent oil
to the middle of the seal level sight gauge (14)
and
maintain it at the middle of the gauge. Clean and
reinstall the vented plug. Maintain the oil at this
level.
NOTE
The white reflector in the sight gauge must be posi
tioned horizontally to provide proper drainage.
Bearings
(Figure 2)
The bearing housing was fully lubricated when
shipped from the factory. Check the oil level regu
larly through the bearing cavity sight gauge (14)
and maintain it at the middle of the gauge. When
lubrication is required, add SAE No. 30 non‐deter
gent
oil through the hole for the air vent (12).
Do not
over‐lubricate. Over‐lubrication can cause the
bearings to over‐heat, resulting in premature bear
ing failure.
NOTE
The white reflector in the sight gauge must be posi
tioned horizontally to provide proper drainage.
Under normal conditions, drain the bearing hous
ing once each year and refill with approximately 24
ounces (710 ml) of clean oil. Change the oil more
frequently if the pump is operated continuously or
installed in an environment with rapid temperature
change.
Monitor the condition of the bearing lubri
cant regularly for evidence of rust or mois
ture condensation. This is especially im
portant in areas where variable hot and
cold temperatures are common.
For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.
Power Source
Consult the literature supplied with the power
source, or contact your local power source repre
sentative.