S SERIES PUMPS
OM-06111
MAINTENANCE AND REPAIR
PAGE E - 24
stored in a clean, tightly closed container in a rea
sonably dry environment.
Table E-2. Oil Quantity
Pump Model
Seal Cavity
Motor Cavity
S6A
832 ounces (24,6 liters)
176 ounces (5,2 liters)
Table E‐3. Pump Oil Specifications
Specifications:
Type
Premium high viscosity index, anti‐wear hydraulic oil
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Viscosity (SSU @ 104
F [40
C])
110 to 155
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dielectric
26,000 (volts‐min)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Acceptable alternate suppliers:
Gulf Oil Company
Gulf Harmony AW Hydraulic Fluid MG 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Texas Oil Company
Rando HD 32 or HD AZ 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sun Oil Company
Sunvis 816 or 916
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BP (Also Boron)
Energol‐HLP 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shell Oil Company
Tellus 32, Tellus T‐23 or T32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Viscosity (SSU @ 210
F [100
C])
40 to 50
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recommended supplier:
Gulf Oil Company
Gulf Harmony 32 AW
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ARCO
Duro 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Exxon (Also Esso)
Nuto H 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Petro‐Canada
Harmony HVI 22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor Housing Cavity
With the pump in an upright position, remove the
pipe cap (43) on the top of the pump. See Table E‐2
and add the recommended grade of lubricant
(Table E‐3) to the motor cavity.
Maintain the oil at
this level
. Apply `Loctite Pipe Sealant With Teflon
No. 592' or equivalent sealant to the threads of the
street tee assembly (44). Reinstall and tighten the
cap.
Never attempt to fill the motor cavity
through the pipe plug opening. A volume
of air must be trapped above the motor to
permit thermal expansion of the motor oil.