4.
SPECIAL FEATURES.
4.1.
Password change
1. LED must flash.
F
+
2. Press -
F
until the LED remains lit.
3.
Press -
4.
Release F
key and immediately release (maximum 0.5s).
5.
Enter old password.
6.
Enter new password (any combination of the keys
F
C
4 characters).
4.2.
Signaling PAGER low power state.
•
BAT – must be set if PAGER is powered by a 9V battery
•
AKU – be set if PAGER is powered by a 8.4V battery / NiMH (Nickel Metal Hydride)
Changing the type of power without a change in the settings (BAT / AKU) will malfunction PAGER.
4.3.
Selecting the operating mode.
•
PNH (frequent monitoring)– if PAGER is to receive signals directly from the transmitter or retransmitter.
•
RTS (longer pause in listening) – if the system signals from all transmitters are passed by retransmitter
(type RTS 100).
RTS Mode allows extra time for battery "life", but it requires that all signals from the transmitters were
transmitted by the retransmitter. Due to the fact that PAGER in this mode goes to sleep for a longer period of time, it
cannot "hear" short signals from transmitters. The signal from the transmitter by a retransmitter is extended
accordingly
.
4.4.
The choice of memory capacity.
This parameter allows you to specify the maximum number of transmitters that can be programmed into PAGER memory
from 10 to 500, in increments of 10 transmitters. The greater the number of transmitters closer to the memory limit
makes the reaction time slightly higher (1s with a limit of 500
).
4.5.
Erasing memory „KASO”
This item is used to delete the total memory pager. For the functions safety has been additionally protected with a
password. Providing an incorrect password takes you "out" to normal operation without the pager erasing the memory
.
Programming SPECIAL FEATURES
1. LED must flash.
+
2. Press -
until the LED remains lit.
3.
Press -
4.
Releaase the
key and quickly release the key (maximum 0.5s).
5.
Enter password.
6.
Press -
F
please go to AKU/ BAT.
7.
Press -
C
and release.
8.
Whith the
/
keys select the PNH/ RTS mode.
9.
Press the key
C
and release it.
10.
The key
/
selects the desired maximum number of transmitters that can
be program in the memory of the pager.
11.
Press the key -
C
and let go – it shows „KASO” – memory erasing.
*
Pressing the key
C
exits the programming mode without erasing the memory of transmitters
*
Pressing the key
F
then re-enter the password, which will erase all transmitters from
memory. Wait until the pager reaches the position of 4499, after which it automatically exits
the reset function.
5.
EVENT LOG.
If PAGER receives and decodes the signals from the transmitters, and they will not be deleted, it will be automatically
preserved in the memory of events. Then, every 30s PAGER gives out two short beeps that will remind of the signals
stored in the memory of events
.
You can use at any time the specific keys
/
to view the event log, also you can press the key
C
to delete
individual events (remembering that the first resets audible signal, then the information from the display).
After a power cut memory of the event is canceled. The event memory can be read up to 500 events back.
Page: 3 of 4