11) REPLACING THE INJECTORS
The burners can be adapted to different types of
gas by mounting injectors suited to the type of gas
in question. To do this, first remove the burner tops
using a wrench “B”. Now unscrew injector “A” (see
fig. 13) and fit a injector corresponding to the
utilized type of gas in its place.
It is advisable to strongly tighten the injector in
place.
After the injectors have been replaced, the
burners must be regulated as explained in
paragraphs 10. The technician must reset any
seals on the regulating or pre-regulating devices.
The envelope with the injectors and the labels
can be included in the kit, or at disposal to the
authorized customer Service Centre.
For the sake of convenience, the nominal rate table
also lists the heat inputs of the burners, the
diameter of the injectors and the working pressures
of the various types of gas.
CONVERSIONS
BURNER ARRANGEMENT ON THE HOT PLATE
FIG. 13
BURNERS
GAS
NORMAL
PRESSURE
m b a r
NORMAL
RATE
INJECTOR
DIAMETER
1/100 mm
NOMINAL HEAT
INPUT (W)
N°
DESCRIPTION
g/h
l/h
Min.
Max.
1
Ultra Rapid
G30 - LPG (20Y)
G20 - NATURAL (12T)
28
20
291
381
72 B x 2 + 46 B
115 A x 2 + 71 A
1800
1800
4500
4500
2
Ultra Rapid
G30 - LPG (20Y)
G20 - NATURAL (12T)
28
20
291
381
72 B x 2 + 46 B
115 A x 2 + 71 A
1800
1800
4500
4500
4
Auxiliary
G30 - LPG (20Y)
G20 - NATURAL (12T)
28
20
73
95
50
72 X
450
450
1000
1000