8
Instructions for liquid gas (LPG: G30, G31)
Tighten the screw on the side of the tap, rod clockwise completely.
Warning: these tasks may only be carried out by a qualified technician, authorized by the gas distributing
company or authorized service center!
TECHNICAL INFORMATION (TAB.1)
426147
426150
439193
426152
426160
426167
439192
426164 - 426162
426166 - 450420
426158 - 426153
453969
426149
Operating voltage
220-240 V~ ; 50/60 Hz
Burner
A: Auxiliary burner (1,0 kW)
SR: Semirapid burner (1,75 kW)
R: Rapid burner (3,0 kW)
MW: Mini-Wok Burner (3,3 kW)
TC: Triple Crown Burner (3,8 kW)
Front left
R
MW
A
TC
R
Rear left
SR
SR
SR
-
-
Front central
-
-
TC
A
SR
Rear central
-
-
-
SR
A
Front right
A
A
SR
SR
SR
Rear right
SR
SR
R
R
-
Category Gas usage
G20 = 20mbar , G30/G31 = 28-30/37mbar
Total Power (W)
7500
7800
11300
11300
7500
NOZZLE TABLE
Burner
A
SR
R
MW
TC
Rated heat output (kW)
1,00
1,75
3,00
3,30
3,80
Reduced Rate (kW)
0,45
0,70
1,00
1,50
1,80
Ø INJECTOR (mm)
G30/G31
28-30/37mbar
0,50
0,65
0,85
0,85
0,98
G20
20mbar
0,72 - X
0,97 - Z
1,28 - H3
1,28 - T
1,35 - K
Ø BY-PASS (mm)
G30/G31
28-30/37mbar
0,27
0,34
0,42
0,55
0,62
G20
20mbar
REG.
REG.
REG.
REG.
REG.